Hello,
My profile
Change password
Sign out
My ETAP
Sign in
Create account
English
español
Search
Toggle navigation
Solutions
Design
Low Voltage Electrical Design
System Modeling & Visualization
Automated Protection & Coordination
Arc Flash Safety - ArcSafety, ArcFault
Renewables & Energy Storage
Distribution Network Analysis
Dynamics & Transients
Grid Code Compliance & Maintenance
AC & DC Rail Traction Systems
Build
Electrical Equipment Design and Engineering
Electrical Manufacturing
Operate
Power Management System
Energy Management System
Advanced Distribution Management System
Digital Substation & Automation System
Relay Protection & Asset Management
Operator Training Simulator
Electrical SCADA & Control System
Automate
Load Shedding Controller
Distribution Load Shedding
Power Plant Controller
Microgrid Controller & Energy Management
Digital Transformation
ETAP Digital Twin
Intelligent Electrical Single-Line Diagram
Sustainability
Data Exchange
Data & Project Management
Cloud - Collaborative Project Management
Mobile - Data Collection App
Solutions for Sectors
Generation
Transmission
Distribution
Industrial
Transportation
Low Voltage
Catalog
View Catalog
Industries
Industry Segments
Engineering Consulting
Data Centers
Energy & Chemicals
Transportation
Manufacturing
Fossil Fuel Generation
Metals & Mining
Nuclear Generation
Renewables
Utility Distribution
Utility Transmission
Government & Defense
Academia
Products
Top Products
Electrical Network Design
ETAP Power Simulator
ETAP eTraX
Caneco
Caneco BT
Caneco Electrical
Caneco BIM
Analysis & Simulation
ETAP Arc Flash
ETAP Protection & Coordination
ETAP Power Flow
ETAP Dynamics & Transients
ETAP Distribution Network Analysis
ETAP Sustainability Analysis
Engineer & Build
SEE Electrical
SEE Electrical Expert
SEE Electrical 3D Panel
SEE Electrical PLM
SEE System Design
Operate & Maintain
ETAP SCADA
ETAP ADMS
ETAP Power Management System
ETAP Generation Management System
ETAP Operator Training Simulator
ETAP Protection Asset Management
SEE Gen eDoc
Automate & Optimize
ETAP Intelligent Load Shedding
ETAP Microgrid
ETAP Power Plant Controller
Data & Project Management
ETAP Mobile APP
ETAP NetPM
SEE Web Catalogue
Caneco Manufacturer Partners
Explore
Caneco
ETAP
SEE
What's New
How to Buy
News
View Detail
View all Products
Events
Events Schedule
ETAP Spark - Regional User Conferences
Nuclear Utility Conference
User Groups
Resources
Resource Center
Case Studies
Caneco Manufacturer Partners
Media Kits
Blogs
Support
Sales Support
Technical Support
Quality Assurance
CANECO/SEE Customer Portal
Services
Analytical Services
System Integration & Automation
Dynamic Modeling & Tuning
GIS Integration
Data Exchange Services
Specification for Power System Analysis
R&D Services
Company
About Us
Why ETAP
Contact Us
News
Awards
Sustainability
Subscribe to News
Global Presence
Partner Program
Careers
Compliance & Ethics
User Lists
Testimonials
Blogs
Request Demo
Get Pricing
Protection & Selectivity in Industrial Facilities
Nov 9, 2021, 00:00 AM
Duration :
14:56
External URL :
https://www.youtube.com/embed/mrn1Qz2Pdks
PETRONAS RAPID project is the largest oil & gas refinery and petrochemical plant in Malaysia which is powered by a 1200MW utilities plant and connected to a 275kV Grid supply.
The integrated ETAP model for the RAPID complex reached up to 5000 buses that consist of various distribution voltages from 400V up to 275kV. Protection Coordination evaluation study for the RAPID complex was performed using “PD Sequence-of-Operation” to identify abnormal relay behavior, which may not be observed in the conventional TCC curve. When simulating earth fault at 275kV system, there is sympathetic relay operation at all 275kV healthy feeders due to circulating earth fault current. The circulating earth fault current is more than 1pu, which will potentially cause a broader outage to the RAPID complex. Further analysis has been performed by the author and academician experts to ascertain the root cause of the circulating earth fault current.
This presentation will discuss the root cause of sympathetic relay operation during 275kV earth fault simulations and the recommended solutions to mitigate the sympathetic operation. This will help engineering design firms and plant operators clearly understand the protection relay behavior during faults by utilizing ETAP special features.
Categories :
Case Study
Tags :