Power System Analysis
| Day | Morning | Afternoon |
|---|---|---|
| 1 | ETAP Company Background ETAP Global Offices ETAP & Supporting Various Industries ETAP & Power System Solutions Quality Assurance, Technical Support & Trainings | Data Requirements Calculation Methods Load / Generation Modeling in Power System Loading / Generation Categories Exercise Cable Editor / Library Cable Manager Cable Loading Cable Installation Types / Ampacity Cable Sizing Standards Cable Sizing Constraints Exercise |
| 2 | Transformer Sizing Concept Temperature Correction Altitude Correction Load Variation Sizing Requirements Load Criteria Results Exercise Short Circuit Study, Evaluation & Result Analyzer - IEC Data Requirements IEC 909 Calculation Method Types of Short Circuit in IEC & Factors Device Duty Calculation in Mesh & Non-Mesh Networks Unbalanced / Ground Faults IEC 61363 Transient Fault Current Calculation Parameter Settings / Adjustments Reports / Alerts Result Analyzer Exercises | |
| 3 | Protective Device Coordination/Selectivity of Equipment Data Requirement | Protective Device Coordination / Selectivity / Sequence-of-Operation Data Requirements Protection Equipment Library Protection & Selectivity Concepts Protective Device Arrangements Time-Current Characteristics Protective Device Coordination utilizing Short Circuit Parameter Settings / Adjustment Sequence-of-Operation Study Auto Coordination Concept & Application Study / Device Setting Reports Exercise |
| 4 | AC Arc Flash Analysis & Result Analyzer AC Arc Flash Concept & Overview Calculation Methods (NFPA 70E and IEEE 1584) Data Requirements PPE Requirements Parameter Settings / Adjustments Effects of Short Circuit & Protection / Coordination Reports / Alerts Result Analyzer Arc Flash Labels Exercises AF Boundary, Incident Energy Plots Analyzing IEEE 1584-2018 & 2002 Differences Current Limiting Breaker (Annex I) & Fuse Equations (Annex H) Conductor Material & 3-P to 1-P Conversion Factors Constant Incident Energy Plots Import & Export – Batch Processing | Harmonics Studies & Filter Sizing Data Requirements Harmonic Source Modeling Harmonic Library / Inter-Harmonics Harmonic Load Flow / Frequency Scan Parameter Settings / Adjustment Reports / Alerts / Plots Exercise Plot Analyzer for graphical plot results comparison & evaluation Live One-Line Diagram plots for graphical results Improved progress bar status, view elapsed & remaining time |
| 5 |
Workshop Description
- The purpose of this introductory hands-on workshop is to learn power system modeling & analysis using ETAP software extended to four days.
- This workshop covers a range of ETAP functionalities used to solve various power system practical problems such as equipment sizing in steady state and short circuit conditions, motor acceleration scenarios, protection of the equipment, selectivity, & device coordination, and effects of harmonics in the system.
Requirements:
- Windows 10 Computer (i5+ CPU)
- Reliable Internet access so attendees can connect to the ETAP License server during the workshop
- Dual monitors are highly recommended.
Who should attend
- New ETAP users and power engineers who wish to increase their skills using the ETAP application to perform system studies
- Current users seeking a refresher course
- Knowledge of power system engineering concepts is highly recommended for those attending this workshop
Registration
Location
Live Online
Date & Time
Nov 16 - 20, 2026
5:00 PM - 1:00 AM
Time zone: UTC
Meal
Hotel
Information
ETAP - Kuala Lumpur
ETAP Automation Sdn Bhd., Level 19, Tower B, Plaza 33, No. 1, Jalan Kemajuan, Seksyen 13, Selangor Darul Ehsan
46200 Petaling Jaya
,
Malaysia
+603-7650 9229
support.apac@etap.com
ETAP Training Services | (949) 900-1084 | training@etap.com
