Power System Analysis
| Day | Morning | Afternoon |
|---|---|---|
| 1 | ETAP Menu and Toolbars Modeling of Power System Components Manual / Auto Building One Line Diagram Display Options Themes and Color Codes Project Revisioning 3-D Database (Presentation, Configuration, Revision) ETAP Library Structure Data Import / Export Data / Project Management Scenario Wizards Exercise | Data Requirements Calculation Methods Load / Generation Modeling in Power System Loading / Generation Categories Diversity / Demand Factors Parameter Settings / Adjustments Reports / Alerts Result Analyzer Exercise Cable Editor / Library Cable Manager Cable Loading Cable Installation Types / Ampacity Cable Sizing Standards Cable Sizing Constraints Exercise |
| 2 | Short Circuit Study, Evaluation & Result Analyzer - IEC Data Requirements IEC 909 Calculation Method Types of Short Circuit in IEC & Factors Device Duty Calculation in Mesh & Non-Mesh Networks Unbalanced / Ground Faults IEC 61363 Transient Fault Current Calculation Parameter Settings / Adjustments Reports / Alerts Result Analyzer Exercises | Motor and motor starting theory Static motor starting analysis Study case editor Motor parameter estimation Dynamic motor starting analysis Plots, display results and reports |
| 3 | Protective Device Coordination / Selectivity Protection of Equipment | Protective Device Sequence-of-Operation Protective Device Coordination utilizing Short Circuit Parameter Settings / Adjustment Sequence-of-Operation Study Study / Device Setting Reports Exercise Auto Evaluation of Protection & Selectivity Protective Device Coordination utilizing Short Circuit |
| 4 | AC Arc Flash Analysis & Result Analyzer AC Arc Flash Concept & Overview Calculation Methods (NFPA 70E and IEEE 1584) Data Requirements PPE Requirements Parameter Settings / Adjustments Effects of Short Circuit & Protection / Coordination Reports / Alerts Result Analyzer Arc Flash Labels Exercises | Harmonics Studies & Filter Sizing Data Requirements Harmonic Source Modeling Harmonic Library / Inter-Harmonics Harmonic Load Flow / Frequency Scan Parameter Settings / Adjustment Reports / Alerts / Plots Exercise |
| 5 | ||
| 6 | ||
| 7 |
Workshop Description
- The purpose of this 4-day introductory hands-on workshop is to learn power system modeling & analysis using ETAP software.
- This workshop covers a range of ETAP functionalities used to solve various power system practical problems such as equipment sizing in steady state and short circuit conditions, motor acceleration scenarios, protection of the equipment, selectivity, & device coordination, arc flash assessment & mitigation, and effects of harmonics in the system.
Who should attend
- New ETAP users and power engineers who wish to increase their skills using the ETAP application to perform system studies.
- Current users seeking a refresher course.
- Knowledge of power system engineering concepts is highly recommended for those attending this workshop.
Registration
Fee: R 15,000
Location
Intergraph Systems Southern Africa
2nd Floor, Building 1, Golder House
Maxwell Office Park, Magwa Crescent West
Waterfall City, Midrand
Johannesburg, South Africa
Date & Time
8:00 AM - 4:30 PM
Meal
Hotel
Information
Intergraph Systems SA (Pty) Ltd
,
South Africa
ETAP Training Services | (949) 900-1084 | training@etap.com
