Power System Analysis
| Day | Morning | Afternoon |
|---|---|---|
| 1 | ETAP Company Background ETAP Global Offices ETAP & Supporting Various Industries ETAP & Power System Solutions Quality Assurance, Technical Support & Trainings | Data Requirements Calculation Methods Load / Generation Modeling in Power System Loading / Generation Categories Diversity / Demand Factors Parameter Settings / Adjustments Reports / Alerts Result Analyzer Exercise |
| 2 | Short Circuit Study & Evaluation - ANSI ANSI Short Circuit Concept & Overview Data Requirements ANSI Calculation Method 1/2 Cycle, 4 Cycle, 30 Cycle Short Circuit Device Duty Calculation Three Phase Faults Unbalanced / Ground Faults Parameter Settings / Adjustments Reports / Alerts Result Analyzer Exercises Short Circuit Study, Evaluation & Result Analyzer - IEC Data Requirements IEC 909 Calculation Method Types of Short Circuit in IEC & Factors Device Duty Calculation in Mesh & Non-Mesh Networks Unbalanced / Ground Faults IEC 61363 Transient Fault Current Calculation Parameter Settings / Adjustments Reports / Alerts Result Analyzer Exercises | AC Arc Flash Concept & Overview Calculation Methods (NFPA 70E and IEEE 1584) Data Requirements PPE Requirements, Parameter Settings / Adjustments Effects of Short Circuit & Protection / Coordination Reports / Alerts Result Analyzer Arc Flash Labels Exercises Enhanced IEEE 1584 Parameters AC Arc Flash Analysis & Result Analyzer AC Arc Flash Concept & Overview Calculation Methods (NFPA 70E and IEEE 1584) Data Requirements PPE Requirements Parameter Settings / Adjustments Effects of Short Circuit & Protection / Coordination Reports / Alerts Result Analyzer Arc Flash Labels Exercises |
| 3 | Underground Cable Thermal Analysis Data Requirements Conduit, Raceway, Duct Bank & Heat Source Modeling Calculation Methods / Settings Temperature / Ampacity Calculation Transient Temperature Calculation Cable Sizing Reports / Alerts / Plots Exercise | Protective Device Coordination / Selectivity / Sequence-of-Operation Data Requirements Protection Equipment Library Protection & Selectivity Concepts Protective Device Arrangements Time-Current Characteristics Protective Device Coordination utilizing Short Circuit Parameter Settings / Adjustment Sequence-of-Operation Study Auto Coordination Concept & Application Study / Device Setting Reports Exercise |
| 4 | ||
| 5 | ||
| 6 | ||
| 7 |
Workshop Description
- The purpose of this 3-day introductory hands-on workshop is to learn power system modeling & analysis using ETAP software.
- This workshop covers a range of ETAP functionalities used to solve various power system practical problems such as equipment sizing in steady state and short circuit conditions, protection & coordination, arc flash assessment & mitigation, and ground grid systems.
- Supporting materials will be provided in PDF, a computer student, certificate of attendance.
- The course is taught in Spanish.
- An ETAP workstation is provided for each attendee.
Who should attend
- New ETAP users and power engineers who wish to increase their skills using the ETAP application to perform system studies
- Current users seeking a refresher course
- Knowledge of power system engineering concepts is highly recommended for those attending this workshop
Registration
Fee: € 970
Registro y coste: 1.500 + I.V.A. El pago es por transferencia a favor de Genin & Garcés S.L. IBERCAJA IBAN: ES47 2085 9276 37 0330496
Location
Centro Empresarial El Coloso
Calle Leganitos 15-18
28013 Madrid
Tel: 915 59 01 42
Date & Time
9:00 AM - 6:00 PM
Meal
Hotel
Information
Genin & Garces
Calle Pollensa, 2 Edificio Artemisa, Planta 1, Oficina 9.1 Las Rozas 28290, Madrid, España.
Las Rozas de Madrid, 28230
Spain
+34 918496224
+34 9185 10026
info@garces-es.com
ETAP Training Services | (949) 900-1084 | training@etap.com