127 Item(s) found

StarZ - Protection & Coordination Analysis

StarZ - Protection & Coordination Analysis

Per North American Electric Reliability Corporation (NERC), 28% of protective relay mis-operations are due to incorrect settings and logics. These errors mainly stem from the existing relay testing procedures that do not provide a proper mechanism to easily and effectively evaluate the performance of all settings, logics, and the protection system as a whole. ETAP StarZ™ is a new solution to minimize protective relay setting errors and reduce the time required to perform protection and coordination studies.

Power Quality - Fundamentals of Harmonics

Power Quality - Fundamentals of Harmonics

This webinar presents the fundamentals of harmonics, harmonic distortion and its sources, and related issues such as premature equipment failure or unplanned downtime.
The presentation will demonstrate how to identify, analyze, and minimize or eliminate harmonics problems using the ETAP software.

Induction Machine - Machine Fundamentals

Induction Machine - Machine Fundamentals

This webinar covers machine fundamentals such as Conversion of Energy, Steady-State Operation, Motor / Generator, Ratings & Motor Equations, Efficiency & Power Factor vs. Loading, Motor Feeder Cable and Load Flow Solutions.

Induction Machine - Machine Dynamic Behavior

Induction Machine - Machine Dynamic Behavior

This webinar discusses the induction motor dynamic behavior for acceleration, deceleration and steady-state speed control conditions. It highlights how each of the key fundamental motor dynamic characteristics applies to different applications such as motor starting, fast-bus transfer, and motor parameter estimation and tuning.

Induction Machine - Motor Protection

Induction Machine - Motor Protection

This webinar presents the criterion and industry guidelines for protection of motors in medium and low voltage systems, typical induction motor protection schemes and suggested settings for protective devices. The application of Automated Protection & Coordination evaluation tool for design, verification, and correction of settings are also demonstrated.

ETAP Project Merge - Project Collaboration & Data Management

ETAP Project Merge - Project Collaboration & Data Management

Watch this webinar on project merge and learn how to use project merge to improve productively and accelerate project schedules.

User-Defined Dynamic Models (UDM)

User-Defined Dynamic Models (UDM)

The User-Defined Dynamic Models (UDM) program allows for a more robust “element-level” and “plant-level” control system simulation. ETAP UDM performance is optimized for simulation of energy storage devices, wind turbine controls, PV system inverters, and generic machine models.

Comparative Study of DC Arc Flash Analysis Methods in ETAP

Comparative Study of DC Arc Flash Analysis Methods in ETAP

In the absence of a "definitive" DC arc flash model, ETAP includes three calculation models - the "Maximum Power" method that is used in NFPA 70E, a model based on the Stokes/Oppenlander estimate of arc voltage and resistance, and a model based on Paukert's complication of research into arcing faults.

Star™ Auto-Evaluation: Automated Protection & Coordination Design

Star™ Auto-Evaluation: Automated Protection & Coordination Design

This presentation will highlight how Star Auto-Evaluation software can improve your system design, safety, reliability and operation. Validate protective device settings for equipment protection, identify mis-coordination and fix zone selectivity issues, apply industry rules for system protection & coordination and significantly increase efficiency, accuracy, and design consistency.

Short Circuit Result Analyzer

Short Circuit Result Analyzer

This webinar will present the new Short Circuit Analyzer. This time-saving feature compares and filters various short circuit reports in a single display.