Protective Device Coordination & Selectivity
Protection & Coordination / Selectivity Analysis
Descripción general
ETAP Star™ overcurrent device protection and coordination evaluation software provides an intuitive and logical approach to Time-Current Characteristic curve selectivity analysis.
ETAP Star offers insight into troubleshooting false trips, relay mis-operation, and mis-coordination.
- Time-Current Characteristic (TCC) Curve
- Protective Device Coordination & Selectivity
- Sequence-of-Operation
- Protection Zone Selection & Viewer
- Automated Protection & Coordination
- Zone Selective Interlock Scheme
- Protective Device Design Assessment
- Verified & Validated Protective Device Libraries
Soluciones relacionadas
Lea sobre las soluciones donde se destaca este producto.
Paquetes relacionados
Encuentre un paquete que incluya este producto como parte de su colección.
Industrias relacionadas
Descubra cómo se utiliza este producto en diversas industrias.
Sistemas relacionados
Conozca los usos de este producto dentro de un sistema de ingeniería.
Testimonios
Preguntas frecuentes
Videos
Protection & Coordination Studies with ETAP Star
ETAP Star™ is an easy-to-use, interactive, and powerful platform for overcurrent protection and coordination studies. Supported with 100+ thousands of verified and validated protective device and equipment library models from manufacturers across the world, simulation and analysis of any network are at your fingertips. Learn about the intuitive and efficient approach for the creation of Time-Current Characteristic Curves and the program’s artificial intelligence (AI) for protection and coordination or selectivity analysis.
A Comprehensive Approach to Protective Device Coordination
The design, sizing, and regulation of the protection system are still one of the major challenges for the integrity and continuity of operation of the power system despite the continuous technology evolution. Protection system shall be capable to continuously monitor the power system, operate quickly and selectively under hundreds of transitory conditions for any type of fault without false trips with the objective to minimize outages, improve safety, and maximize service continuity. This presentation covers a real case study for an expansion of a brownfield industrial installation with new equipment that prompted the need for modification of existing protective device settings thus, requiring revision and re-validation of the coordination studies. The case study will demonstrate how ETAP software features and capabilities were utilized to verify the new / recommended settings to address the protection & coordination objectives and arc flash hazard impact.
ABB FCL Application Engineering for IS-Limiters
This presentation will feature covert ABB Fault Current Limiter (FCL) application engineering for Is-limiters. We will explain the fault current limiter technology by using the well-known ABB FCL Is-limiter. The FCL technology will be introduced, how it clears a short-circuit fault current compared to a standard circuit breaker, and the major components of an FCL. The theory of the application engineering process and the calculation of the tripping value for an FCL will be introduced. Based on an actual customer project, it will be shown how ETAP has facilitated the complex FCL application engineering, and examples will be provided of how the real tripping value for a fault current limiter is determined. The session will conclude with an overview of how etap can already be used today for an FCL application engineering and what will be enhanced in the future.
Protection & Selectivity in Industrial Facilities
PETRONAS RAPID project is the largest oil & gas refinery and petrochemical plant in Malaysia which is powered by a 1200MW utilities plant and connected to a 275kV Grid supply. The integrated ETAP model for the RAPID complex reached up to 5000 buses that consist of various distribution voltages from 400V up to 275kV. Protection Coordination evaluation study for the RAPID complex was performed using “PD Sequence-of-Operation” to identify abnormal relay behavior, which may not be observed in the conventional TCC curve. When simulating earth fault at 275kV system, there is sympathetic relay operation at all 275kV healthy feeders due to circulating earth fault current. The circulating earth fault current is more than 1pu, which will potentially cause a broader outage to the RAPID complex. Further analysis has been performed by the author and academician experts to ascertain the root cause of the circulating earth fault current. This presentation will discuss the root cause of sympathetic relay operation during 275kV earth fault simulations and the recommended solutions to mitigate the sympathetic operation. This will help engineering design firms and plant operators clearly understand the protection relay behavior during faults by utilizing ETAP special features.
Star™ Auto-Evaluation: Automated Protection & Coordination Design
This presentation will highlight how Star Auto-Evaluation software can improve your system design, safety, reliability and operation. Validate protective device settings for equipment protection, identify mis-coordination and fix zone selectivity issues, apply industry rules for system protection & coordination and significantly increase efficiency, accuracy, and design consistency.
ETAP Star - Making a User Curve - Part 1
There are cases when a user needs to draw specific curves onto a Star TCC presentation which is not included in the ETAP Star standard library. Applying ETAP "User Curve" is the solution for that.
ETAP Star - Making a User Curve - Part 2
There are cases when a user needs to draw specific curves onto a Star TCC presentation which is not included in the ETAP Star standard library. Applying ETAP "User Curve" is the solution for that.
Capacitación y eventos
Capacitación y eventos
Obtenga una visión en profundidad de nuestro software de ingeniería eléctrica solicitando un curso de capacitación que se adapte a usted.