Power System Analysis
Day | Morning | Afternoon |
---|---|---|
1 | ETAP Menu and Toolbars Modeling of Power System Components Manual / Auto Building One Line Diagram Display Options Themes and Color Codes Exercise | 3-D Database (Presentation, Configuration, Revision) ETAP Library Structure Data Import / Export Data / Project Management Scenario Wizards Exercise |
2 | Data Requirements Calculation Methods Load / Generation Modeling in Power System Loading / Generation Categories Diversity / Demand Factors Parameter Settings / Adjustments Reports / Alerts Result Analyzer Exercise | Short Circuit Study & Evaluation - ANSI ANSI Short Circuit Concept & Overview Data Requirements ANSI Calculation Method 1/2 Cycle, 4 Cycle, 30 Cycle Short Circuit Device Duty Calculation Three Phase Faults Unbalanced / Ground Faults Parameter Settings / Adjustments Reports / Alerts Result Analyzer Exercises |
3 | Protective Device Coordination / Selectivity Protection of Equipment Protective Device Sequence-of-Operation Protective Device Coordination utilizing Short Circuit Parameter Settings / Adjustment Sequence-of-Operation Study Study / Device Setting Reports Exercise Auto Evaluation of Protection & Selectivity Auto Evaluation Concept & Application Auto Evaluation Rule Book Auto Evaluation of Protection & Coordination on Selected Zones Errors, Alerts & Warnings Exercise | AC Arc Flash Analysis & Result Analyzer AC Arc Flash Concept & Overview Calculation Methods (NFPA 70E and IEEE 1584) Data Requirements PPE Requirements Parameter Settings / Adjustments Effects of Short Circuit & Protection / Coordination Reports / Alerts Result Analyzer Arc Flash Labels Exercises Model Range & New Study Case Options |
4 | ||
5 | ||
6 | ||
7 |
Workshop Description
- This introductory workshop begins with the basics of one-line diagram creation, data entry, and quickly expands the users’ knowledge to include methods to automatically perform multiple ‘what if’ studies using multiple scenarios.
- The workshop includes Short-Circuit, Load Flow, Device Coordination, and detailed Arc Flash Analysis.
- Other topics such as Motor Starting, Ground Grid Design, Cable Pulling, Harmonic Analysis, Parameter Estimation, Cable Pulling, Transient Stability, Generator Start-Up, Optimal Power Flow, Reliability Assessment, Unbalanced Power Flow, DC Load Flow, DC Short Circuit, Battery Sizing & Discharge, Control System Diagrams, Wind Turbine Analysis, etc. are available via onsite training courses or attendance to advanced sessions.
- An ETAP workstation is provided for each attendee.
Who should attend
- New ETAP users and power engineers who wish to increase their skills using the ETAP application to perform system studies.
- Current users seeking a refresher course.
- Engineers that have an electrical background, but haven't taken formal ETAP training before.
- Knowledge of power system engineering concepts is highly recommended for those attending this workshop.
Registration
Fee: CAD 2,995
All courses are LIMITED to 20 or less participants, so please register early!
Contact: training@etap.ca
Location
Versalys
Suite 1010, 1440, St. Catherine St. W, 10th Floor
Montreal, QC, H3G 1R8, Canada
(514) 844-2300
(No direct parking; various lots available in the area)
Date & Time
8:30 AM - 4:30 PM
Meal
Hotel
All travel and hotel arrangements are the responsibility of the attendees.
Nearby hotels:
Best Western Plus Montreal Downtown
1240, Drummond St, Montreal, Canada
(514) 866-6492
Le Centre Sheraton
1201, Rene-Levesque Blvd E, Montreal, Canada,
(514) 878-2000
Comfort Suites Downtown
1214 Crescent St, Montreal, Canada
(514) 878-2711
Information
ETAP Canada Ltd.
1289-91st Street SW
Suite 102
Edmonton, AB T6X1H1
Canada
+1 (780) 758 0500
+1 (866) 821 3732
sales@etap.ca
ETAP Training Services | (949) 900-1084 | training@etap.com