Controllers & Remote Terminal Units

Controllers & Remote Terminal Units

etap iCE™ - Intelligent Control Enterprise Hardware

Power System Data Acquisition, Monitoring & Remote Control Solution
etap iCE™ Intelligent Control Enterprise hardware product platform includes programmable control and Remote Terminal Unit (RTU) integrated with ETAP Real-Time™ solutions for optimal performance, fast response, and cyber security. 
etap iCE RTU Hardware

Remote Terminal Units

  • Substation Data Acquisition & Control
  • Field / pole-mount RTU
  • Feeder Remote Terminal Unit - FRTU
  • Integrated Fault Detector

Controllers

  • Substation Automation
  • Intelligent Load Shedding
  • Generation Control
  • Data Acquisition
  • Secure & Scalable Controller

etap iCE Key Features

  • Programmable Controller
  • Remote Terminal Unit - RTU
  • Data Acquisition & Control
  • Integrated Fault Detector
  • Fault Tolerant Hardware
  • High Performance & Availability
  • Built-In Redundancy
  • Secure Controller
  • Communication Protocols
  • Wireless Communications
  • Compliance with international standards
  • IEC62351  Cyber security Compliant
  • IEC61131-3  Automation Logic Programing
  • IEC61850-3  Substation Automation MV & HV Facilities
  • Verified & Validated with ETAP Real-Time™ solutions

RTU & Substation Automation

iCE-RTU

Remote telecontrol unit for HV/MV facilities

iCE-RTU

iCE-GW

Communication gateway for control protocols

iCE-GW

iCE19

19” Rack Mount RTU / Controller

iCE19

Device Communication & Compliance

Communication Protocols

  • IEC 60870-5-101,102,103,104
  • IEC 61850 MMS, GOOSE
  • DNP3.0 Serial & TCP
  • Modbus RTU/TCP
  • Profibus DP
  • Procome
  • DLMS
  • SNMP

IEC62351 Cybersecurity Compliant

  • Role based Access Control (RBAC)
  • Access Control List (ACL)
  • TLS/SSL Incryption
  • HTTPS
  • SSH
  • VPN

Automation Logic Programing

  • IEC61131-3

Time Synchronization

  • NTP
  • IEEE1588
  • IEC60870-5-101
  • DNP 3.0
etap iCE Communication Architecture Diagram

Environmental Compliance

IEC61850-3 Compliant for Substation Automation MV & HV Facilities:

Rated Insulation Voltage

IEC 60255-5:2000 Table I

Dielectric Test Voltage

IEC 60255-5:2000 Table I, Series B (Clause 6)

Insulation resistance test

IEC 60255-5:2000 (Clause 7)

Impulse Voltage Test

IEC 60255-5:2000 (Clause 8)

Electrostatic Discharge Immunity

IEC 61000-4-2

Radiated Immunity

IEC 61000-4-3 // IEC 60255-22-3 // ENV 50204 (GSM)

Electric Fast Transient & Burst Immunity

IEC 61000-4-4 // IEC 60255-22-4 // ANSI/IEEE C37.90.1

Surge Immunity

IEC 61000-4-5

Conducted Immunity

IEC 61000-4-6

Power Frequency Magnetic Field Immunity

IEC 61000-4-8

Pulse Magnetic Field Immunity

IEC 61000-4-9

Damped Oscillatory Magnetic Field Immutity

IEC 61000-4-10

Oscillatory transient immunity

IEC61000-4-12

Electrical Disturbances (1 MHz Burse)

IEC 60255-22-1:2005

High Voltage Impulse

IEC 60060-1

Conducted emissions

EN55022:2000

Signaling voltages

IEC 61000-4-17

Mains frequency voltage

IEC 61000-4-16

Voltage dips

IEC 61000-4-29

Change of temperature

IEC 60068-2-14

Damp heat (long term exposure)

IEC 60068-2-3

Composite temperature/humidity cyclic test

IEC 60068-2-38

Cold

IEC 60068-2-1

Dry heat

IEC 60068-2-2

Damp heat, cyclic (12 h + 12 h cycle)

IEC 60068-2-30

Storage

 

Vibration (sinusoidal)

IEC 60068-2-6

Shock (inside packaging)

IEC 60068-2-27

Applications & Industries

  • eSCADA
  • PMS
  • ADMS
  • Fast Intelligent Load Shedding
  • Distribution Load Shedding
  • SCMS
  • Traction PMS
  • Power Metering

Videos

Literature

ETAP iCE RTU

ETAP iCE RTU

etap iCE Remote Terminal Unit provides a scalable data acquisition and control RTU with multiple communication options.

ETAP iCE Gateway

ETAP iCE Gateway

etap iCE Gateway collects data from multiple devices and protocols and convert them to a single output protocol.

White Papers