Recent Trends
133 Item(s) found
Inclusión de Generación de Energía por Fuentes Renovables en los Sistemas de Potencia
- 1:00:00
- Webinar
Este video muestra funciones de ETAP para hacer un análisis más completo de fuentes de energía renovable en las redes eléctricas, se incluyen en el video arreglos de paneles fotovoltaicos y aerogeneradores. Además, aprenderá a modelar su sistema tomando en cuenta las variaciones de potencia a través del tiempo, propias de este tipo de fuentes con la aplicación de Flujo de Potencia en el Dominio del Tiempo.
IEEE 1584-2018 Arc Flash Incident Energy Calculation Method using ETAP
- 1:24:01
- Webinar
This webinar will provide an overview of the fundamental differences between the IEEE 1584-2018 and existing arc flash methods. To better understand how the 2018 model combines empirical and arc flash physical behavior, the presentation will cover background and insights into the model development validation.
Faulted Circuit Indicators
- 42:50
- Webinar
This webinar covers the process of modeling, simulation and protection & coordination study of distribution feeders equipped with Fault Circuit Indicators in ETAP.
Ground Grid System
- 8:21
- Webinar
Overview on ETAP capabilities in ground grid system design and analysis using IEEE 80 Standard and Finite Element Method (FEM).
Cable Ampacity, Sizing & Shock Protection - Part II
- 28:31
- Webinar
Proper sizing and current de-rating ensures that cables operate to their maximum potential while providing secure and reliable operation. This webinar covers cable sizing, current carrying capacity and electrical shock protection based on IEC and British standards.
Directional Overcurrent Protection of a Wind Farm Collector
- 47:54
- Webinar
The challenges of directional protection of a wind farm collector are presented in this webinar. ETAP StarZ™ Protection & Coordination module is utilized to set and analyze protection of wind power plant collectors.
StarZ - Protection & Coordination Analysis
- 44:37
- Webinar
Per North American Electric Reliability Corporation (NERC), 28% of protective relay mis-operations are due to incorrect settings and logics. These errors mainly stem from the existing relay testing procedures that do not provide a proper mechanism to easily and effectively evaluate the performance of all settings, logics, and the protection system as a whole. ETAP StarZ™ is a new solution to minimize protective relay setting errors and reduce the time required to perform protection and coordination studies.
Power Quality - Fundamentals of Harmonics
- 37:09
- Webinar
This webinar presents the fundamentals of harmonics, harmonic distortion and its sources, and related issues such as premature equipment failure or unplanned downtime.
The presentation will demonstrate how to identify, analyze, and minimize or eliminate harmonics problems using the ETAP software.
Induction Machine - Machine Fundamentals
- 41:07
- Webinar
This webinar covers machine fundamentals such as Conversion of Energy, Steady-State Operation, Motor / Generator, Ratings & Motor Equations, Efficiency & Power Factor vs. Loading, Motor Feeder Cable and Load Flow Solutions.
Induction Machine - Machine Dynamic Behavior
- 1:21:03
- Webinar
This webinar discusses the induction motor dynamic behavior for acceleration, deceleration and steady-state speed control conditions. It highlights how each of the key fundamental motor dynamic characteristics applies to different applications such as motor starting, fast-bus transfer, and motor parameter estimation and tuning.