Integrated Arc Flash Software Suite

AC Arc Flash

IEEE 1584-2018, NFPA 70E


ArcFault™ - High Voltage Arc Flash

OSHA 1910.269, National Electrical Safety Code - NESC

DC Arc Flash

NFPA 70E, Maximum Power, Stokes & Oppenlander and Paukert


Arc Flash Calculators

IEEE 1584-2018, BGI/GUV-I 5188, DC and High Voltage Arc Flash


All-in-one software solution for performing AC and DC arc flash analysis on LV, MV, and HV systems.

 

IEEE 1584-2018 Arc Flash Incident Engery Calculation Method

IEEE 1584-2018 Arc Flash Calculation

The 2018 IEEE 1584 model supersedes the IEEE 1584-2002 model. Learn how the IEEE 1584 2018 model combines empirical and arc flash physical behavior. Learn more


High Voltage Arc Flash for T&D, Industrial and Renewable Systems

ArcFault™ - High Voltage Arc Flash

Arc Flash analysis software for electric power systems operating at 15 kV and above in compliance with OSHA’s requirements for electrical transmission, distribution, industrial and renewable energy systems. Learn more

Arc Flash Analysis for 1 kV to 800 kV

  • OSHA 1910.269
  • National Electrical Safety Code - NESC
  • LG, LL, 3-Phase arc faults
  • Arc-in-a-box - 15 kV to 36 kV

Direct Current Arc Flash Analysis

ETAP DC Arc Flash software calculates the incident energy for different types of direct current applications, including mission critical facilities, electrochemical plants, substation battery banks, photovoltaic plants, nuclear plants, and transportation systems. Learn more

DC Arc Flash Incident Energy Calculation

  • Incident energy & shock protection boundary calculations
  • Maximum Power, Stokes & Oppenlander, Paukert Methods
  • NFPA 70E 2018 Annex D.5.1 to D.5.3

Arc Flash Calculators

Arc Flash Calculators

Quick ‘What-if’ Scenarios & Instant Result Visualization

ETAP Arc Flash Calculators provide a powerful graphical tool for rapid assessment of multiples or batches of “what if” scenarios.

Graphical Arc Flash Calculators

  • IEEE 1584-2018 Std. Arc Flash Calculator
  • IEEE 1584-2002 Std. CL Fuse & Breaker Calculator
  • DC Arc Flash Calculator
  • High Voltage Arc Flash Calculator – OSHA, NESC
  • BGI/GUV 5188E German Std. Arc Flash Calculator

Safety & Protection Software Modules

Get special competitive discount on Safety & Protection Software Package


Additional Resources
Ground Grid Design Made Simple

Ground Grid Design Made Simple

In this webinar, learn how to obtain accurate and economical ground grid designs by quickly identifying appropriate ground grid layouts, while efficiently conducting studies using integrated fault analysis tools.
High Voltage Arc Flash for T&D, Industrial and Renewable Systems

High Voltage Arc Flash for T&D, Industrial and Renewable Systems

El análisis de arco eléctrico se extiende más allá del alcance de la metodología IEEE 1584 y NFPA 70E para sistemas de transmisión, distribución, industriales y de energía renovable. Durante muchos años, a la industria le ha faltado una solución "todo en uno" para realizar análisis de arco eléctrico de CA y CC en sistemas de LV, MV y HV.
IEEE 1584-2018 Arc Flash Incident Energy Calculation Method using ETAP

IEEE 1584-2018 Arc Flash Incident Energy Calculation Method using ETAP

Este seminario web proporcionará una visión general de las diferencias fundamentales entre el IEEE 1584-2018 y los métodos de arco eléctrico existentes. Para comprender mejor cómo el modelo 2018 combina el comportamiento físico empírico y de arco eléctrico, la presentación cubrirá los antecedentes y los conocimientos sobre la validación del desarrollo del modelo.
ETAP Arc Flash

Arco eléctrico

Introducción a ETAP Arc Flash, módulo de análisis. Aprende cómo empezar con Arc Flash.
Watch how ETAP can help in your industry sector