ETAP Cable Sizing software provides various options which can be used for design requirements. These design requirements can be user-defined or automatically determined from load flow, short circuit, and protective device calculation results.
ETAP cable sizing study module calculates optimal and alternative cable sizes for phase conductors based on the following criteria:
The user can size cables by specifying constraint based on maximum allowable cable voltage drop in percent.
This cable sizing calculation program allows you to calculate cable size based on electric motor minimum allowable starting voltage.
ETAP’s cable sizing analysis software can compute the size of the cables based on cable short-circuit capacity to withstand the short-circuit current. The short circuit current can be specified manually or obtained from the short circuit calculation.
Cable sizing software computes the size of the cable by also considering overload protection. ETAP cable sizing program calculates the minimum size required by meeting the overload protection conditions between derated ampacity, operating current and nominal current. The option to size based on overload current is only enabled when BS 7671 17th Edition or IEC 60364 standards are selected for cable sizing.
If the neutral conductor carries current without any reduction in the load of line conductors, the harmonic current distortion in the neutral conductor needs to be considered in the determination of the current carrying capacity of the circuit. ETAP Cable Sizing module considers zero sequence / triple harmonic constraints as well as other harmonic constraints based on correction / reduction factors for other order of harmonics. The option to size based harmonic spectrum is only enabled when BS 7671 17th Edition or IEC 60364 standards are selected for cable sizing.
The cable sizing calculator applies a multiplication factor to the cable ampacity based on the cable application selected. These multiplications factors can be applied to the calculated ampacity as well.
The Standard field displays the standard selected in the Ampacity page. When the Load Amp requirement is selected in the Requirements section, the ampacity calculation in cable sizing will be based on the standard displayed.
Using the selected cable type from the library, ETAP recommends an optimal cable size along with the number of conductors per phase that meets the specified requirements. Additionally, ETAP cable sizing module provides one cable size smaller than the optimal size for your selection. For the voltage results, Vd is in percent based on bus nominal kV and Vst is in percent based on motor rated kV. Along with the cable sizing calculation results, this section also displays the required cable sized, cable ampacity, percent of voltage drop, and percent of starting voltage if cable sizing options for the corresponding requirements are checked. The required cable size is the largest size from Short-Circuit, Overload, and Shock requirements. The requirement ampacity is the larger value from Load Amp and Overload requirements. Note that if the Use MF for Ampacity option is selected, the Load Amp used for cable sizing will be multiplied by the MF value displayed in the Cable Application section.
The user can select one or both requirements for determining the recommended size of cable in the cable sizing software. Note that some of the options are dependent on the installation type and if the cable is an equipment cable for a motor.
If Load Amp is selected as one of the requirements, cable sizing will be conducted to meet the load current requirement based on the cable installation and ambient conditions specified in the Cable Ampacity page. The load ampere value is displayed here based on the option selected in the Loading Current for cable Sizing section in the Loading page.
If Vd is selected, ETAP will size the cable based on the percent voltage drop value you enter here. Voltage drop is in percent of nominal kV of the bus connected to the cable. If the nominal voltages of the From Bus and To Bus are different, nominal kV of the From Bus is selected. The following table shows the methods used for voltage drop calculation for different types of load currents flowing through the cable.
Entdecken Sie Add-ons und andere verwandte Produkte.
Alle Produkte anzeigen
Lesen Sie über Lösungen, bei denen dieses Produkt hervorgehoben wird.
Alle Lösungen anzeigen
Suchen Sie ein Paketbündel, das dieses Produkt als Teil seiner Kollektion enthält.
Alle Pakete ansehen
A complete solution for your cable system needs
Entdecken Sie, wie dieses Produkt in verschiedenen Branchen eingesetzt wird.
Alle Branchen anzeigen
Laut der im EC&M Magazine veröffentlichten Liste der Top 40 Elektrodesignfirmen verlassen sich 100 % der Top 10 Elektrodesignfirmen auf ETAP
Erfahren Sie mehr über die Verwendungsmöglichkeiten dieses Produkts in einem technischen System.
Alle Systeme anzeigen
Alle Ressourcen anzeigen
Proper sizing and current derating ensures that cables operate to their maximum potential while providing secure and reliable operation. Learn about design and application requirements to properly size and analyze cable system based on IEEE and North American cable standards and guidelines
Proper sizing and current de-rating ensures that cables operate to their maximum potential while providing secure and reliable operation. This webinar covers cable sizing, current carrying capacity and electrical shock protection based on IEC and British standards.
This Cable Thermal Analysis webinar explains how to design cable systems to operate to their maximum potential while providing a secure and reliable operation.
ETAP NF C15-100 & NF C13-200; Cable Sizing & Shock Protection software module offers a powerful tool to save time and improve accuracy for low & high voltage cable calculation and electrical design using the latest French Cable Standard.
Erhalten Sie einen vertieften Einblick in unsere Elektrotechnik-Software und fordern Sie eine für Sie passende Schulung an.
Jetzt entdecken
Testen Sie ETAP 30 Tage lang kostenlos und überzeugen Sie sich selbst von den Leistungsfähigkeit der ETAP-Lösungen. Testen Sie ETAPs umfangreiche Sammlung an Modulen und Analyseergebnissen auf dieser Cloud-basierten Demo-Plattform – jederzeit und überall. Starten Sie noch heute Ihre Online-Demo!