Transmission & Distribution Protection - StarZ™
T&D Protection & Coordination Analysis Software - StarZ™
- Evaluate & Verify Protection & Coordination
- Reduce Human Error in Relay Settings & Logic
- Simulate Model-Specific Protection Settings & Functions
- Offer Distance, Overcurrent, Directional, Differential, Load Encroachment and other functions
- Employ Advanced Power Flow & Fault Analyses for Unbalanced Network
- Simulate protection based on Unbalanced Faults
- Create and Manage StarView TCCs in StarZ mode
- Use Real-Time Operational Data for System Evaluation
- Virtually Animate Sequence-of-Operation of Protective Devices
- Comprehensive relay library including impedance-based functions
Videos
How to perform protection & coordination studies for traction systems with ETAP's StarZ module
ETAP Train Power Simulation - eTraX™ software includes validated, user-friendly and flexible software tools for designing, analyzing and managing AC and DC railway infrastructure. Learn how eTraX integrates with ETAP protection & coordination software (StarZ) to offer insights into line protection, protective relay performance & evaluation, troubleshooting false trips, and system-wide protective device operation.
Integrated Stability & Protection Sequence of Operation
Many protection functions such as over/under frequency, out-of-step, generator loss of excitation are set based on power system dynamic characteristics. These protection functions were conventionally set with the assumption that, system dynamics are predictable using simplistic and aggregated models. Higher penetration of distributed energy resources (DERs) has made power system dynamics considerably more complex to predict through conventional approaches. ETAP offers a new solution to perform unified protection and transient stability study to accurately capture interactions between system dynamics and protection system. This solution allows protection engineers and network planners to 1- tune protection settings to act properly during system dynamics, 2- design and test remedial protection schemes, 3- evaluate all protection functions such as out-of-step, overcurrent and generator loss of excitation protection function and 4- perform grid code studies that require evaluating DER performance along with its protection system.
StarZ - Protection & Coordination Analysis
Per North American Electric Reliability Corporation (NERC), 28% of protective relay mis-operations are due to incorrect settings and logics. These errors mainly stem from the existing relay testing procedures that do not provide a proper mechanism to easily and effectively evaluate the performance of all settings, logics, and the protection system as a whole. ETAP StarZ™ is a new solution to minimize protective relay setting errors and reduce the time required to perform protection and coordination studies.
Literature
White Papers
Schulungen und Veranstaltungen
Schulungen und Veranstaltungen
Erhalten Sie einen vertieften Einblick in unsere Elektrotechnik-Software und fordern Sie eine für Sie passende Schulung an.