296 Item(s) found
Motor Acceleration Studies
- 34:53
- Webinar
Learn how to perform Motor Acceleration Studies on any system, regardless of the project stage and available input data; from conceptual design, to FEED, to daily operations. Topics include Impact of Motor Starting, Data Requirements and Motor Parameter Estimation, Dynamic Motor Starting, Motor Acceleration using Transient Stability and Automated Motor Start and Result Analyzer.
eMTCoSim™ - CoSimulation of Electromagnetic & Phasor Transients
- 32:31
- Webinar
Learn how ETAP Transient Stability program and Electromagnetic Transients Program (eMT) are combined in eMTCoSim mode to provide hybrid simulations of Phasor and Transients domains to collectively solve large, complex, and multi-disciplinary system models with higher fidelity.
ETAP 20 - A Unified Digital Twin Platform
- 01:15:09
- Webinar
ETAP 20 Release makes advances in data management, efficiency, flexibility, interoperability, asset modeling, and network analysis applications. In this webinar, learn about some of the significant features and powerful capabilities that are a must have in your power system tool-set.
Intelligent Microgrid Management - Part 1
- 49:25
- Webinar
ETAP's μGrid™ solution combines model-driven microgrid controller hardware with advanced power management software to unlock system resiliency, optimized cost, security, and sustainability. This webinar focuses on microgrid design and software-based validation.
ETAP Digital Twin: Design, Operation & Automation
- 35:12
- Webinar
Battery Energy Storage Systems
- 59:58
- Webinar
This webinar demonstrated how the integration of battery energy storage systems improves system reliability and performance, offers renewable smoothing, and can increase profit margins of renewable farm owners.
Voltage Stability Analysis
- 34:54
- Webinar
ETAP Voltage Stability software helps to accurately identify the system maximum load carrying capacity limits and reactive power compensation requirements. In this webinar, learn how to identify voltage stability limits, simulate the impact of voltage instability, perform sensitivity analysis, calculate & report instability indices and assess results via network views & plots.
NetPM™ Network Project Modeling & Management
- 21:53
- Webinar
This webinar introduces ETAP NetPM™ and demonstrates how this powerful time-saving solution for topology synchronization, data integration, model coordination & validation, and information transfer benefits users across the entire life cycle of the electrical network from modeling to operation and from engineering-consultants to owner-operators.
ETAP iCE RTU
etap iCE Remote Terminal Unit provides a scalable data acquisition and control RTU with multiple communication options.
ETAP iCE Gateway
etap iCE Gateway collects data from multiple devices and protocols and convert them to a single output protocol.
ETAP Real-Time™ - Overview
Fully integrated suite of software products that provides mission critical power management solutions, from modeling to real-time, model-based monitoring and operation.
Cable Sizing per NF C15-100 & NF C13-200
- 19:14
- Webinar
Cable Sizing & Shock Protection software module offers a powerful tool to save time and improve accuracy for low & high voltage cable calculation and electrical design using the latest French Cable Standard.
Cable Thermal Analysis - Part III
- 40:00
- Webinar
This Cable Thermal Analysis webinar explains how to design cable systems to operate to their maximum potential while providing a secure and reliable operation
High Voltage Arc Flash for T&D, Industrial and Renewable Systems
Arc flash analysis extends well beyond the scope of IEEE 1584 and NFPA 70E methodology for transmission, distribution, industrial and renewable energy systems. For many years, the industry has been lacking an ‘all-in-one’ solution for performing AC and DC arc flash analysis on LV, MV, and HV systems.
IEEE 1584-2018 Arc Flash Incident Energy Calculation Method using ETAP
- 1:24:01
- Webinar
This webinar will provide an overview of the fundamental differences between the IEEE 1584-2018 and existing arc flash methods. To better understand how the 2018 model combines empirical and arc flash physical behavior, the presentation will cover background and insights into the model development validation.
IEEE 1584-2018 Arc Flash Incident Energy Calculation
New Standard, New Method, New Learning Curve
Cable Ampacity, Sizing & Shock Protection - Part II
- 28:31
- Webinar
Proper sizing and current de-rating ensures that cables operate to their maximum potential while providing secure and reliable operation. This webinar covers cable sizing, current carrying capacity and electrical shock protection based on IEC and British standards.
Directional Overcurrent Protection of a Wind Farm Collector
- 47:54
- Webinar
StarZ - Protection & Coordination Analysis
- 44:37
- Webinar
Per North American Electric Reliability Corporation (NERC), 28% of protective relay mis-operations are due to incorrect settings and logics. These errors mainly stem from the existing relay testing procedures that do not provide a proper mechanism to easily and effectively evaluate the performance of all settings, logics, and the protection system as a whole. ETAP StarZ™ is a new solution to minimize protective relay setting errors and reduce the time required to perform protection and coordination studies.