267 Item(s) found
ETAP iCE Gateway
etap iCE Gateway collects data from multiple devices and protocols and convert them to a single output protocol.
ETAP Real-Time™ - Overview
Fully integrated suite of software products that provides mission critical power management solutions, from modeling to real-time, model-based monitoring and operation.
Cable Sizing per NF C15-100 & NF C13-200
- 19:14
- Webinar
Cable Sizing & Shock Protection software module offers a powerful tool to save time and improve accuracy for low & high voltage cable calculation and electrical design using the latest French Cable Standard.
Cable Thermal Analysis - Part III
- 40:00
- Webinar
This Cable Thermal Analysis webinar explains how to design cable systems to operate to their maximum potential while providing a secure and reliable operation
High Voltage Arc Flash for T&D, Industrial and Renewable Systems
Arc flash analysis extends well beyond the scope of IEEE 1584 and NFPA 70E methodology for transmission, distribution, industrial and renewable energy systems. For many years, the industry has been lacking an ‘all-in-one’ solution for performing AC and DC arc flash analysis on LV, MV, and HV systems.
IEEE 1584-2018 Arc Flash Incident Energy Calculation Method using ETAP
- 1:24:01
- Webinar
This webinar will provide an overview of the fundamental differences between the IEEE 1584-2018 and existing arc flash methods. To better understand how the 2018 model combines empirical and arc flash physical behavior, the presentation will cover background and insights into the model development validation.
IEEE 1584-2018 Arc Flash Incident Energy Calculation
New Standard, New Method, New Learning Curve
Cable Ampacity, Sizing & Shock Protection - Part II
- 28:31
- Webinar
Proper sizing and current de-rating ensures that cables operate to their maximum potential while providing secure and reliable operation. This webinar covers cable sizing, current carrying capacity and electrical shock protection based on IEC and British standards.
Directional Overcurrent Protection of a Wind Farm Collector
- 47:54
- Webinar
StarZ - Protection & Coordination Analysis
- 44:37
- Webinar
Per North American Electric Reliability Corporation (NERC), 28% of protective relay mis-operations are due to incorrect settings and logics. These errors mainly stem from the existing relay testing procedures that do not provide a proper mechanism to easily and effectively evaluate the performance of all settings, logics, and the protection system as a whole. ETAP StarZ™ is a new solution to minimize protective relay setting errors and reduce the time required to perform protection and coordination studies.
Power Quality - Fundamentals of Harmonics
- 37:09
- Webinar
This webinar presents the fundamentals of harmonics, harmonic distortion and its sources, and related issues such as premature equipment failure or unplanned downtime.
The presentation will demonstrate how to identify, analyze, and minimize or eliminate harmonics problems using the ETAP software.
ETAP ADMS™ - Advanced Distribution Management System
ETAP ADMS™ is a combined planning and operation solution to manage, control, visualize, and optimize electrical power distribution network comprising of GIS, SCADA, DMS, DNA & OMS.
Induction Machine - Machine Fundamentals
- 41:07
- Webinar
This webinar covers machine fundamentals such as Conversion of Energy, Steady-State Operation, Motor / Generator, Ratings & Motor Equations, Efficiency & Power Factor vs. Loading, Motor Feeder Cable and Load Flow Solutions.
Induction Machine - Machine Dynamic Behavior
- 1:21:03
- Webinar
This webinar discusses the induction motor dynamic behavior for acceleration, deceleration and steady-state speed control conditions. It highlights how each of the key fundamental motor dynamic characteristics applies to different applications such as motor starting, fast-bus transfer, and motor parameter estimation and tuning.
Induction Machine - Motor Protection
- 1:05:59
- Webinar
This webinar presents the criterion and industry guidelines for protection of motors in medium and low voltage systems, typical induction motor protection schemes and suggested settings for protective devices. The application of Automated Protection & Coordination evaluation tool for design, verification, and correction of settings are also demonstrated.
What You Always Wanted From A Power Management System
Vital features and benefits of the modern power management software.