Harmonic Analysis Software


Harmonics

Harmonic Analysis

개요

With the Harmonic Analysis module, you can simulate harmonic current and voltage sources, identify harmonic problems, reduce nuisance trips, design and test filters, and report harmonic voltage and current distortion limit violations.

Comprehensive load flow and frequency scan calculations are performed using detailed harmonic source models and power system component frequency models. Results are shown graphically, including harmonic order, harmonic spectrum plots, and harmonic waveform plots, as well as Crystal Reports.

Complied Harmonic Standards:

  • IEEE 519
  • ANSI/IEEE 399
  • IEEE 141
  • IEEE 519-2014 - MV / HV / EHV
  • IEC 61000-3-14 - LV
  • IEC 61000-3-6
  • IEEE Standard 519-1992  
  • IEEE Standard 519-2022 
  • IEEE Std 3002.8,  
  • IEEE Std 1547-2018,  
  • IEEE Std 2800-2022 
  • IEEE Std. 1531-2020 

One-line diagram with 5th, 7th, and 11th harmonics

Harmonic Analysis Software Key Features

  • Harmonic Frequency Scan Software
  • Harmonic Filters & Sizing Software
  • Rule book for voltage and current distortion
  • Harmonic voltage and current distortion evaluation (THD & IHD)
  • Harmonic telephone influence factors (TIF & I*T)
  • Automatic alerts of harmonic violations
  • Typical and user definable harmonic sources library
  • Variable Frequency Drive (VFD) harmonic modeling
  • UPS AC input and output harmonic modeling
  • Photovoltaic array inverter harmonic modeling
  • WTG Type 4 harmonic modeling
  • Harmonic Grid Code Compliance
  • Embedded Newton-Raphson and Gauss-Seidel load flow methods
  • Harmonic current injection method
  • Integrated with cable sizing in order to size cables based on harmonic load flow
  • Transformer and cable derating alerts 
  • Transformer K-Factor Calculation 
  • Total Rated Distortion alerts for branches at reference point of applicability when IBRs and DERs are installed 
  • User definable interharmonic page in the harmonic source library 
Harmonic frequency scan with results printed on a one-line diagram

Harmonic Load Flow Capabilities

  • User-expandable harmonic source library
  • Modeling voltage & current harmonic sources
  • Considering both harmonic source magnitudes & phase angles
  • Global, local & individual location compliance rule book for voltage & current distortion
  • Harmonic source based spectrum or device parameters
  • Transformer K-Factor calculation
  • Temperature-dependent line & cable resistances
  • Automatic adjustment of equipment impedance to harmonic frequency
  • Includes phase shifting transformers
  • Built-in single-tuned, high-pass, & band-pass harmonic filter models
  • Size and tune passive harmonic filters to shift resonance points to less harmful frequencies
  • Identify harmonic distortion problems
  • Identify & analyze telephone interference problems by harmonics
  • Identify parallel resonance conditions
  • Fundamental load flow results
  • IEEE 519 defined harmonic indices
  • Skin effect models for motors & transformers
  • TDD and TRD current distortion limit evaluation
  • Enhanced load equipment cable modeling
  • Voltage and Current distortion alerts with percentile multipliers
  • Total & harmonic voltage & current
  • Harmonic Distortions (THD & IHD)
  • Root Mean Square Values (RMS)
  • Voltage Arithmetic Summation (ASUM)
  • Telephone Interference Factor (TIF)
  • I*T product
  • Time-domain waveform plots
  • Frequency-domain harmonic spectrum plots
  • Harmonic filter performance evaluation
  • Report voltage & current harmonic distortions
  • Report RMS, ASUM, TIF, & I*T values
  • Text output reports including harmonic violation flags
  • Graphical one-line display of harmonic results
  • Voltage & current harmonic spectrum plots
  • Export one-line diagrams to third party CAD systems
  • Fundamental load flow results
  • Use Crystal Reports® for full color, customizable reports
  • Export output reports to your favorite word processor
  • Multiple plot database comparison in single window using Plot Analyzer™ tool

관련 상품

추가 기능 및 기타 관련 제품을 살펴보세요.

모든 제품 보기

관련 솔루션

이 제품이 강조된 솔루션에 대해 읽어보세요.

모든 솔루션 보기

관련 패키지

이 제품이 컬렉션의 일부로 포함된 패키지 번들을 찾아보세요.

모든 패키지 보기

관련 산업

이 제품이 다양한 산업에서 어떻게 사용되는지 확인해 보세요.

모든 산업 보기

관련 시스템

엔지니어링 시스템 내에서 이 제품의 사용법을 알아보세요.

모든 시스템 보기

추천사

자주 묻는 질문

    How to perform Harmonic Analysis with ETAP

    How to perform Harmonic Analysis with ETAP

    Learn how engineers use ETAP Harmonic Analysis software to simulate harmonic current and voltage sources, identify harmonic problems, reduce nuisance trips, design, and test filters, and report harmonic voltage and current distortion limit violations on balanced or unbalanced systems. Additionally, for transmission and distribution system operators, Harmonic Grid Code automates harmonic analysis for detailed power quality assessment reporting demonstrating the generation facility is designed to comply with applicable harmonic limits. Study reports include worst-case incremental and total harmonic distortion, frequency-dependent Thevenin Equivalent at PCC, and color-coded impedance loci charts.

    Play 37:49
    Power Quality - Fundamentals of Harmonics

    Power Quality - Fundamentals of Harmonics

    This webinar presents the fundamentals of harmonics, harmonic distortion and its sources, and related issues such as premature equipment failure or unplanned downtime.
    The presentation will demonstrate how to identify, analyze, and minimize or eliminate harmonics problems using the ETAP software.

    Play 37:09

    교육 및 이벤트

    ETAP Training

    교육 및 이벤트

    귀하에게 맞는 교육 과정을 요청하여 전기 엔지니어링 소프트웨어에 대한 심층적인 통찰력을 얻으세요.

    지금 발견하세요