Cable Systems

케이블 시스템

ETAP 케이블 시스템은 신뢰성 있는 운영을 제공함과 동시에 최대 전위를 운영하기 위한 케이블 시스템을 설계할 수 있으며 수행과정 또한 체계적이고 간단합니다. 
  • Cable Sizing

    Calculate optimal & alternative cable sizes

  • Cable Thermal Analysis

    Design, analyze, and size cables in underground raceway systems

  • Cable Pulling

    Cable pulling tension calculator using 3D graphcial layout

  • PE 도체 사이징

    보호 대지접지/접지 도체 사이징 계산 툴

  • Underground Conductor Electromagnetic Fields

    Determine if the magnetic fields generated by underground conductors exceed health & safety exposure limits for workers & public

  • NEC NFPA 70

    Cable ampacity calculation based on National Electrical Code

  • IEEE(전기, 전자 기술자 협회 규격) 399

    산업 및 상업 전력 계통의 IEEE(전기,전자 기술자 협회 규격)에 권장사례를 기반으로 한 케이블 전류용량 계산

  • ICEA P-54-440

    Cable ampacity calculation based on ICEA / NEMA standard for cable tray installations

  • IEC 60502

    Current carrying capacity calculations for high voltage power cables per IEC 60502

  • IEC 60364

    Current carrying capacity calculations for low voltage cables per IEC 60364-5-52 & IEC 60364-4-41

  • IEC 60092

    Current carrying capacity calculations for power cables in ships & offshore units

  • BS 7671

    Current carrying capacity & sizing for low voltage cable installations per British Standards

  • NFC 15-100

    프랑스 표준 케이블 전류 용량& 크기:NFC 15-100 설치 électriques à basse tension

  • NF C 13-200

    French Standard for Current Carrying Capacity & Cable Sizing for High Voltage Power Cables

  • AS/NZS 3008

    Cable current carrying capacity & sizing based on AS/NZS 3008

Key Features

    Videos

    Cable Ampacity & Sizing

    Cable Ampacity & Sizing

    Proper sizing and current derating ensures that cables operate to their maximum potential while providing secure and reliable operation. Learn about design and application requirements to properly size and analyze cable systems based on IEEE and North American cable standards and guidelines: IEEE 399, ICEA P-54-440, NEC NFPA 70

    Cable Ampacity, Sizing & Shock Protection - Part II

    Cable Ampacity, Sizing & Shock Protection - Part II

    Proper sizing and current de-rating ensures that cables operate to their maximum potential while providing secure and reliable operation. This webinar covers cable sizing, current carrying capacity and electrical shock protection based on IEC and British standards.

    Cable Thermal Analysis - Part III

    Cable Thermal Analysis - Part III

    This Cable Thermal Analysis webinar explains how to design cable systems to operate to their maximum potential while providing a secure and reliable operation.

    Cable Sizing per NF C15-100 & NF C13-200

    Cable Sizing per NF C15-100 & NF C13-200

    Cable Sizing & Shock Protection software module offers a powerful tool to save time and improve accuracy for low & high voltage cable calculation and electrical design using the latest French Cable Standard.

    Literature

    Cable Magnetic Field Evalution Calculation

    Cable Magnetic Field Evalution Calculation

    The magnetic field exposure analysis tool uses balanced & unbalanced load-flow currents and angles to determine the location of the worst-case magnetic field exposure due to conductors in underground raceways.

    White Papers