高調波解析ソフトウェア

Harmonics

Harmonic Analysis

With the Harmonic Analysis module, you can simulate harmonic current and voltage sources, identify harmonic problems, reduce nuisance trips, design and test filters, and report harmonic voltage and current distortion limit violations.
One-line diagram with 5th, 7th, and 11th harmonics
Comprehensive load flow and frequency scan calculations are performed using detailed harmonic source models and power system component frequency models. Results are shown graphically, including harmonic order, harmonic spectrum plots, and harmonic waveform plots, as well as Crystal Reports.

Complied Harmonic Standards:
  • IEEE 519
  • ANSI/IEEE 399
  • IEEE 141
  • IEEE 519-2014 - MV / HV / EHV
  • IEC 61000-3-14 - LV
  • IEC 61000-3-6

Harmonic Analysis Software Key Features

  • Harmonic Frequency Scan Software
  • Harmonic Filters & Sizing Software
  • Rule book for voltage and current distortion
  • Harmonic voltage and current distortion evaluation (THD & IHD)
  • Harmonic telephone influence factors (TIF & I*T)
  • Automatic alerts of harmonic violations
  • Typical and user definable harmonic sources library
  • Variable Frequency Drive (VFD) harmonic modeling
  • UPS AC input and output harmonic modeling
  • Photovoltaic array inverter harmonic modeling
  • WTG Type 4 harmonic modeling
  • Harmonic Grid Code Compliance
  • Embedded Newton-Raphson and Gauss-Seidel load flow methods
  • Harmonic current injection method
  • Integrated with cable sizing in order to size cables based on harmonic load flow
Harmonic frequency scan with results printed on a one-line diagram

Harmonic Load Flow Capabilities

  • User-expandable harmonic source library
  • Modeling voltage & current harmonic sources
  • Considering both harmonic source magnitudes & phase angles
  • Global, local & individual location compliance rule book for voltage & current distortion
  • Harmonic source based spectrum or device parameters
  • Model up to the seventy-third (73rd) harmonic
  • Temperature-dependent line & cable resistances
  • Automatic adjustment of equipment impedance to harmonic frequency
  • Includes phase shifting transformers
  • Build-in single-tuned, high-pass, & band-pass harmonic filter models
  • Create harmonic filters to shift resonance points to less harmful frequencies
  • Identify harmonic distortion problems
  • Identify & analyze telephone interference problems by harmonics
  • Identify parallel resonance conditions
  • Fundamental load flow results
  • IEEE 519 defined harmonic indices
  • Skin effect models for motors & transformers
  • Automatic TDD current distortion limit evaluation
  • Enhanced load equipment cable modeling
  • Voltage & current alerts with percentile multipliers
  • Total & harmonic voltage & current
  • Harmonic Distortions (THD & IHD)
  • Root Mean Square Values (RMS)
  • Voltage Arithmetic Summation (ASUM)
  • Telephone Interference Factor (TIF)
  • I*T product
  • Time-domain waveform plots
  • Frequency-domain harmonic spectrum plots
  • Harmonic filter performance evaluation
  • Report voltage & current harmonic distortions
  • Report RMS, ASUM, TIF, & I*T values
  • Text output reports including harmonic violation flags
  • Graphical one-line display of harmonic results
  • Voltage & current harmonic spectrum plots
  • Export one-line diagrams to third party CAD systems
  • Fundamental load flow results
  • Use Crystal Reports® for full color, customizable reports
  • Export output reports to your favorite word processor
  • Multiple plot database comparison in single window using Plot Analyzer™ tool

Videos

How to perform Harmonic Analysis with ETAP

How to perform Harmonic Analysis with ETAP

Learn how engineers use ETAP Harmonic Analysis software to simulate harmonic current and voltage sources, identify harmonic problems, reduce nuisance trips, design, and test filters, and report harmonic voltage and current distortion limit violations on balanced or unbalanced systems. Additionally, for transmission and distribution system operators, Harmonic Grid Code automates harmonic analysis for detailed power quality assessment reporting demonstrating the generation facility is designed to comply with applicable harmonic limits. Study reports include worst-case incremental and total harmonic distortion, frequency-dependent Thevenin Equivalent at PCC, and color-coded impedance loci charts.

Power Quality - Fundamentals of Harmonics

Power Quality - Fundamentals of Harmonics

This webinar presents the fundamentals of harmonics, harmonic distortion and its sources, and related issues such as premature equipment failure or unplanned downtime.
The presentation will demonstrate how to identify, analyze, and minimize or eliminate harmonics problems using the ETAP software.

Literature

White Papers

Training & Events

ETAP Training

Training & Events

Get an in-depth insight to our electrical engineering software by requesting a training course that suits you.

Discover Now