集成的交流和直流设计与分析
模型驱动的SCADA,EMS,PMS,ADMS和SAS
统一数字孪生平台设计,运营和自动化
Intuitive, intelligent, and integrated real-time monitoring via a state-of-the-art interface.
Turnkey SCADA solution with Open Architecture & Native Communications
Device interlocks, system optimization, control inhibits
使用实时和存档的数据预测系统行为,以响应操作员的操作和事件。
Flexible alarm management with power analysis based alarming, real-time data and field device notifications.
评估因果关系调查、系统运行、替代措施和“假设”方案。
Seamless communication with almost any data acquisition system.
Standardized and reusable templates
In recent years, more and more the electrical system generation, transmission, distribution and industrial networks are expanding, being digitized and penetrated with new technologies such as distributed generation. Traditional SCADA solutions are no longer sufficient to support dispatchers and operators to efficiently make decisions during normal and emergency conditions. ETAP eSCADA, based on digital twin technology, supersedes traditional SCADA’s by providing analytical solutions with operator friendly interfaces making data and recommendations available instantaneously. Yet, the system is designed to support complement standard SCADA functionality making it a complete solution. This presentation will cover the capabilities of ETAP eSCADA for operating many different electrical networks.
City of Azusa, California, located east of Los Angeles, serves approximately 17,000 electrical customers. The full-service electric division is committed to providing safe & reliable operations to all customers, from residential to large commercial and industrial. In 2021, the department realized the then-existing infrastructure no longer met their needs and expectations. Relying on different systems for various applications, data management and its transfer has proven inefficient and prone to errors as well as the lack of local support; they recognized the potential of ETAP's fully-integrated, unified SCADA platform.
At a given nuclear power plant, nuclear safety is directly dependent on a reliable source of electric power supplied via the plant’s auxiliary power system. The auxiliary power system typically consists of an MV and LV AC and a DC distribution system, powering thousands of individual loads and circuits, i.e., pumps, fans, valves, sensors, and controls specifically designed to protect the integrity of the nuclear reactor and containment structures. This presentation will explore past practices and recent developments in the online monitoring of such systems using a digital twin. The presentation includes the reasons for utilizing online monitoring, the advantages of using a digital twin versus simple data collection, and the multi-faceted benefits realized from such a system (i.e., business, safety, reliability).
Steel Authority of India Limited (SAIL) is one of the largest steel-making companies in India and one of the Maharatnas of the country’s Central Public Sector Enterprises. ETAP was selected to upgrade the existing SLCC (Supervisory Load Control Centre) System for Power Distribution of Bokaro Steel Plant. This presentation will give insights into the project scope and deployment: The SCADA/PDMS system shall monitor and control the Distribution & Sub-Distribution stations and achieve the SCADA/PDMS functions, integrated with the SLCC control center. Bokaro Steel Plant (BSL) is having a client/server architecture-based SCADA System for monitoring and controlling of generation, import, and distribution of power through SLCC Control room at MSDS-I. The SLCC system is also connected to a central SLCC system located in Kolkata. RTUs for substations will be installed in various locations which are connected through a dedicated fiber-optic network to the server.
ETAP ADMS™ is a combined planning and operation solution to manage, control, visualize, and optimize electrical power distribution network comprising of GIS, SCADA, DMS, DNA & OMS.