269 Item(s) found

How to perform Transmission & Distribution Network Analysis with ETAP Solutions

How to perform Transmission & Distribution Network Analysis with ETAP Solutions

Learn how utility engineers use ETAP’s transmission & distribution system analysis and optimization solutions to optimize capacity planning and improve reliability and safety using schematic or geospatial views. ETAP Grid™ transmission system software integrates transmission network planning with detailed substation models, network topology processing, transmission system analysis, electric SCADA and real-time transmission network energy management system. For integrated distribution network analysis, system planning and operations solution it offers a progressive geospatial platform for simulating, analyzing, operating and optimizing the performance of Utility Smart Grids.

Distribution Network Analysis

Distribution Network Analysis

Alpine Energy Case Study – Building a model for today and the uncertain tomorrow. To maximize the benefit from our ETAP models, we developed a system that makes use of the available features to provide structure to our system models, and allow flexibility to deal with future model expansion and changes. The foundation to achieving this objective was the establishment of a naming convention and model structure that would enable the loading of models and data handling processes to be done with ease. Further enhancing our use of ETAP, we make use of templates and color coding linked to the themes to match the real world network in the modelling world. Lastly, the library was built from scratch and has now matured to a stage where new data is phased in and updated during the validation of models. Following our investment in building our models, in order to maximize the benefit from our ETAP, we developed rigorous processes to ensure accuracy and consistency in building models and managing data. Once data is updated, we utilize ETAP to run Load Flow, Fault Level and Protection Coordination studies and rely on ETAP multi-dimensional database capabilities to set financial years, switching configurations and add new proposed loads to the relevant configuration year. Combining the above features and processes, we have established a disciplined and rigorous Network Development Planning process using ETAP. This has enabled us to plan for the future in an efficient and effective manner. Our ETAP models are benchmarked against actual power system conditions by collecting historical demand data (voltages and currents) from smart meters at customer level, power quality measurement devices at distribution transformers, protection relays at substations, and our SCADA system. But this is not the end, we have developed a future roadmap for our ETAP models with plans to fully integrate with our geospatial information system and our supervisory control and data acquisition (SCADA) environment, to utilize protection coordination, and build smart scenario wizards to do the hard work for us.

ETAP 진보된 배전 관리 시스템에 대해 알아보기 - ADMS

ETAP 진보된 배전 관리 시스템에 대해 알아보기 - ADMS

지리 공간 정보 시스템(GIS), 전기 감시 제어 및 데이터 수집(SCADA), 배전 관리 시스템(DMS), DNA(배전 네트워크 애플리케이션), OMS(사고 관리 시스템)으로 구성된 전력 배전망을 관리, 제어, 시각화 및 최적화하기 위한 통합 계획 및 운영 솔루션인 ETAP ADMS™을 경험해보세요. 애플리케이션은 새로운 디지털 그리드의 핵심 요구 사항을 해결할 수 있는 융통적 해결책을 통해 네트워크에 효율성과 안정성을 제공하는 동시에 운영 결과를 지능적이고 능동적으로 평가할 수 있는 확장성을 갖추고 네트워크 비용을 최소화하고 설비 최적화를 개선할 수 있는 새로운 요구 사항에 기여해야 합니다. ETAP ADMS는 작은 것부터 광대한 배전망 및 스마트 그리드를 안정적이고 안전하게 관리, 제어, 시각화 및 최적화하기 위해 미션 크리티컬 운영 솔루션과 통합된 지리공간 기반 배전망의 모음과 함께 전기 네트워크의 통합 디지털 트윈을 기반으로 하는 지능적이고 강력한 의사 결정 지원 플랫폼을 제공합니다.

ETAP GTDMS - New Frontiers in Digital Transformation for a Sustainable Future

ETAP GTDMS - New Frontiers in Digital Transformation for a Sustainable Future

Learn how utility engineers use ETAP’s transmission & distribution system analysis and optimization solutions to optimize capacity planning and improve reliability and safety using schematic or geospatial views. ETAP Grid™ transmission system software integrates transmission network planning with detailed substation models, network topology processing, transmission system analysis, electric SCADA and real-time transmission network energy management system. For integrated distribution network analysis, system planning and operations solution it offers a progressive geospatial platform for simulating, analyzing, operating and optimizing the performance of Utility Smart Grids.

ETAP 22 - Release Highlights - Sustainability through Continuous Intelligence

ETAP 22 - Release Highlights - Sustainability through Continuous Intelligence

ETAP 22 is released and available for download! The Electrical Digital Twin solution helps you design, operate, and automate safe, reliable, resilient, and compliant power systems - even more efficiently & collaboratively than before, on a single platform, facilitating fully integrated lifecycle digitization.

How to Easily Migrate  from Legacy Software Projects to ETAP

How to Easily Migrate from Legacy Software Projects to ETAP

In this webinar, we demonstrated how easy it is to convert to ETAP 22 from various legacy software applications using the most advanced built-in data conversation tool. We also explored many of the new features & capabilities in ETAP 22 and revealed tips and tricks for the best ETAP experience.

How to perform protection & coordination studies for traction systems with ETAP's StarZ module

How to perform protection & coordination studies for traction systems with ETAP's StarZ module

ETAP Train Power Simulation - eTraX™ software includes validated, user-friendly and flexible software tools for designing, analyzing and managing AC and DC railway infrastructure. Learn how eTraX integrates with ETAP protection & coordination software (StarZ) to offer insights into line protection, protective relay performance & evaluation, troubleshooting false trips, and system-wide protective device operation.

ETAP 22 New Features brochure

ETAP 22 New Features brochure

ETAP 22 offers an impressive new set of integrated power analysis modules, electrical dimensioning capabilities, automation, and operations solutions.

ZSI Scheme for Protective Device Evaluation & Arc Flash Mitigation Technique using ETAP

ZSI Scheme for Protective Device Evaluation & Arc Flash Mitigation Technique using ETAP

ZSI (Zone Selective Interlock) Scheme has been developed about 40 years ago and since then, the application has expanded from Protection to Arc Flash Hazard Mitigation and even Coordination or Selectivity.

ETAP Star™ is an easy-to-use, interactive, and powerful platform for overcurrent protection and coordination studies. Supported with 100+ thousands of verified and validated protective device and equipment library models from manufacturers across the world, simulation and analysis of any network are at your fingertips. Learn about the intuitive and efficient approach for the creation of Time-Current Characteristic Curves and the program’s artificial intelligence (AI) for protection and coordination or selectivity analysis.

In this webinar, we introduce ETAP Unbalanced Network Short Circuit Analysis and demonstrate how to evaluate the impact of shunt and sliding faults on balanced and unbalanced networks: *Device Duty Evaluation for multi-phase, single-phase, AC & DC systems * Run and evaluate all fault types in one study * Shunt, series, and simultaneous faults * Simulate protective device responses to fault currents and configuration changes Unbalanced Network Short Circuit Standards: * ANSI C37.10 for AC systems * IEC 60909 for AC systems * IEC 61660 for DC systems

Review Process in Protection Coordination Studies

Review Process in Protection Coordination Studies

A practical example of an internal review of a protection coordination study, including the definition of protective device settings & characteristics.

Protection Coordination at Panama Mina de Cobre

Protection Coordination at Panama Mina de Cobre

Design and commission of a green-site power system including protection coordination for the entire site and implementation of IEC61850 communications, inter-tripping, inter-locking and protection blocking schemes.

Konexa's Digital Grid Journey

Konexa's Digital Grid Journey

Konexa rolling out its integrated distribution model with multiple DISCOs across Nigeria. In its sub-concession area, Konexa will develop embedded generation capacity (solar PV), and invest in the distribution network (medium voltage line, distribution transformers, injection substations) and last mile reticulation (low voltage lines, smart metering infrastructure). In addition, Konexa will invest in and implement IT & OT systems and processes to drive operational efficiency and significantly reduce ATC&C losses. The first phase of the project would serve about 7,000 customers (C&I and residentials).

Remote Management of Protection Relays

Remote Management of Protection Relays

This presentation defines and demonstrates the importance of remote data collection of protection relays for the security and reliability of large power system networks.  

Oman Electricity Transmission Company grid stations contain more than 5000 rapidly expanding protection relays installed. In case of tripping incidences, the protection system would isolate the faulty primary equipment by actuating the switchgear. These isolated equipment restorations can be done faster if protection relays’ fault records and events can be retrieved through remote access at any time. ETAP and OETC jointly worked to provide remote relay access and data retrieval. The protection system model and relay data feed in a relay management system solution, is called ETAP eProtect. This system is connected through IEC 61850 and IEC 60870-5-103 protocol to linked relays, events, and fault records. Fault records are stored in a database for detailed analysis and validation. This presentation discusses the challenges faced, technical requirements, and benefits of the solution.

Reactive Power based LCOE Analysis

Reactive Power based LCOE Analysis

High penetration of solar PV energy fed into an electrical grid brings its share of challenges making the grid volatile which requires stabilizing variable energy. This presentation addresses one such challenge, of voltage profile improvement with reactive power compensation at the point of interconnection. A solar PV plant is rated in terms of power (either AC or DC) and is typically not rated for their reactive counterparts (MVAr). IEEE 1547/UL 1741 compliant inverters will typically not have reactive power capability and operate with a unity power factor. Although modern inverters have a capacity to supply reactive power in the range of +0.9 lead/-0.9 lag, the PV plant is rated based on the AC power supplied by the inverter at unity PF. Operational data sourced from various plants in India suggest that a typical utility-scale PV plant provides reactive energy in the range of 7% to 10%. This leads to an inherent error in the per-unit cost calculation, as when the inverter providing the reactive power, the active power is hampered. This paper showcases a cost-to-benefit analysis of various scenarios, such as unity power.

Using ETAP to Evaluate Ground Fault Trips in a Microgrid

Using ETAP to Evaluate Ground Fault Trips in a Microgrid

Adding distributed generation sources to existing power distribution systems and the implementation of islanding microgrid capability introduce protection and control challenges if not properly designed.  Each new generator may present a new source ground fault current to the system, which can result in unanticipated breaker operation. Energy Systems Group, was using ETAP to model the system and check coordination of local and remote breakers can reduce downtime and troubleshooting.

Generator Brush Collector Ring’s Arc Flash Hazard, A Safety Concern!

Generator Brush Collector Ring’s Arc Flash Hazard, A Safety Concern!

For some types of generator exciter systems, collector rings and brushes are used to provide energy from the exciter to the rotating field. The brushes wear down and constantly need to be replaced with the unit on-line and while brush/ring assembly is still energized, a risky and unsafe maintenance operation and may cause a serious harm. A potential shock and arc-flash hazard. This presentation addresses the important and dangerous maintenance of worn-down collector rings and brushes, electrical safety, lack of standards and guidelines, and a first possible calculation method.

AC and DC Arc Flash Methods for Renewable Energy Systems

AC and DC Arc Flash Methods for Renewable Energy Systems

This presentation will address the difficulties and lessons learnt on performing arc flash analysis using available methods (outside the voltage limits of IEEE 1584-2018 standard) on a 2.3 MW PV generation facility. The analysis includes system modeling, short-circuit, arc flash (both AC and DC) using various applicable calculation methods that best fit this application along with available tools in ETAP and generating worst-case arc flash deliverables.