Diseño y análisis integrados de CA y CD
SCADA, EMS, PMS, ADMS y SAS basados en modelos
Controladores inteligentes y sistema de gestión
Una plataforma unificada de gemelo digitalDiseño, Operación y Automatización
Filter by
¿No ha encontrado lo que buscaba? Estamos aquí para ayudarle.
278 Item(s) found
The Electrical Risk Management (ERM) group at FTI uses ETAP to provide short circuit, coordination, and arc flash studies as a part of building a safety program for industrial facilities around the US and Canada. This presentation will describe our approach to an overall safety program and the ways that a safety program encompasses more that just an engineering study. Some topics to be discussed are the need for maintenance personnel to understand the labeling, assessing the risk vs. just looking at the label, the choice between full coordination and arc flash hazard, field verification, and bolted fault current vs arcing fault current as it relates to equipment evaluation. We will look at the ETAP model of one of our industrial customers and discuss the benefits of using ETAP for our studies – reliability, adaptability to many systems by using configurations and scenarios, wizards, availability of DC and MV calculations, Star TCCs, ease of exporting reports to Excel, and solar and wind sources capability.
This study simulates the impact of step loading on the transient stability of a 2 x 25 MW GTG-based captive power plant at one of the Chemical Fertilizer Plants located at Trombay, India. The variation of electrical frequency and terminal voltage of the generator during the most conservative step loading of one generator unit is studied. The loads divided in steps are switched at certain time intervals to determine whether the frequency profile of the system is within the acceptable limit of ±5%. Load Flow and Short Circuit Studies are performed on the entire power plant distribution network of the fertilizer plant in advance to check the adequacy of equipment ratings during normal and short circuit conditions with all verified input data. The step load response study is carried out with only one GTG unit running in isolation, feeding only the critical emergency loads. Transient behavior of the GTG unit is simulated with IEEE transfer function dynamic models, viz. AC8B model of excitation system (AVR) and IEEE GGOV1 model for turbine governing system using the in-built standard library in ETAP software version 16.1.0. Various parameters of the generator like speed, active and reactive power, bus voltage, and frequency are plotted for determining the transient performance of the GTG unit.
Learn about ETAP ArcSafety, an all-in-one AC & DC arc flash solution for LV, MV & HV systems that improves safety, reduces risk, minimizes equipment damage, and validates mitigation techniques.
Learn how engineers use ETAP Harmonic Analysis software to simulate harmonic current and voltage sources, identify harmonic problems, reduce nuisance trips, design, and test filters, and report harmonic voltage and current distortion limit violations on balanced or unbalanced systems. Additionally, for transmission and distribution system operators, Harmonic Grid Code automates harmonic analysis for detailed power quality assessment reporting demonstrating the generation facility is designed to comply with applicable harmonic limits. Study reports include worst-case incremental and total harmonic distortion, frequency-dependent Thevenin Equivalent at PCC, and color-coded impedance loci charts.
This webinar outlines how ETAP Microgrid Control Solution devices and implements adaptive strategies to enable a smooth transition between grid-connected and islanded modes during unplanned islanding.
Apply optimal charging, discharging and arbitrage to improve energy efficiency, increase reliability, and reduce customer costs
This webinar introduces an integrated model-driven approach for engineers and managers to design and operat power systems. ETAP’s Digital Twin Platform combines electrical, mechanical, and thermal properties with intelligent visualization for modeling, design, automation, and real-time predictive analysis. Learn how ETAP’s unique multi-dimensional database eliminates the need for hundreds of copies of the project file, by providing unlimited graphical presentations, configurations, data revisions, loadings, generations and operational values within the same project database. Moreover, ETAP unified platform allows simultaneous analysis of the network under various conditions.
Descubra cómo los propietarios, operadores y planificadores utilizan ETAP GIS para diseñar, analizar y expandir mejor sus redes. Discutiremos cómo incluir redes de transmisión, subtransmisión y distribución en un mismo modelo eléctrico y resolver las redes combinadas.
El diagrama digital unifilar inteligente (iSLD), es la representación de su sistema de energía y la base de todos sus estudios de ingeniería eléctrica. Discutiremos su importancia, qué lo hace inteligente, por qué es crucial mantenerlo actualizado y cuál es la mejor manera de hacerlo.