集成的交流和直流设计与分析
模型驱动的SCADA,EMS,PMS,ADMS和SAS
统一数字孪生平台设计,运营和自动化
Filter by
Didn't find what you are looking for? We're here to help!
42 Item(s) found
Join us in a webinar that focuses on new ways to elevate your ETAP software experience, highlighting the significant enhancements you’ll find in ETAP 2024 to boost your productivity. With the new ETAP 2024 Release, we are revolutionizing our software with ETAP PowerRibbon™ - An intuitive user interface that matches the power and precision of ETAP.
Explore our 3D electrical cabinet design software: Harness the power of 3D using a professional intuitive interface, Automate panel mounting and assembly and Reduce design, manufacturing and startup costs.
Discover the new modules and features of ETAP 2024 in a presentation from ETAP CEO, Tanuj Khandelwal to get a high level overview and demonstrations of the impressive array of integrated power analysis modules, model-driven automation and situationally intelligent operation solutions provided in this release. Learn why ETAP 2024 marks a significant advancement in our commitment to delivering innovative technology and industry best practices, to keep your power systems safe, reliable, efficient, sustainable and compliant with the highest industry standards.
In this webinar, we'll provide a comprehensive overview of ETAP eTraX, a powerful solution designed for the design, analysis, optimization and operation of both AC and DC rail traction systems.
Edge control solution for microgrids & distributed energy resources. Mission critical operations need a reliable power system that operates by supplementing the utility grid in parallel mode (tied) or autonomous island mode in a clean, optimized, low cost and resilient manner.
The variable nature of renewable energy introduces power quality concerns, including frequency and voltage control, that may negatively impact the reliable performance of a power system. Grid codes, interconnection, or evacuation criteria must be followed during the proposed system design and continue to maintain compliance under grid-connected operation.
随着全球电力行业迅速向可持续能源转型,电网规范互连研究的重要性变得至关重要。电网规范的手动分析可能非常耗时,涉及复杂的场景和严格的合规性。ETAP Grid Code 是一种模型驱动的解决方案,包括软件工具和控制硬件,以确保整个电力系统设计和运营生命周期内符合当地电网规范或标准。此外,ETAP 独特的发电厂控制器 (ePPC) 及其数字孪生可确保准确评估和研究系统的实际性能,以提高合规性并最大限度地降低风险。
The Red Sea Utility Grid is in the Tabuk province of Saudi Arabia. The site is a vast 33,000 km2 of islands, lagoon, coastal plain and mountains with extremely diverse marine life and terrestrial landforms. The grid is divided into four off-grid microgrids. The focus of this presentation is about three of the microgrids that are very similar in size and operation. Each of these microgrids includes two PV generation (total 6 MW), two battery storages (total 5MW, ~18 MWh), and two emergency backup diesel generators (~ total 3.8 MW). The system is designed to achieve high reliability by having redundancy at various levels.
Large power plants are designed and operated to maximize reliability. This is typically done by having multiple points of interconnection and networked configuration. In case of a failure or loss of one point of interconnection, the plant can be reconfigured by closing a coupling breaker and transferring power to another point of interconnection. However, to ensure optimal operation of the power plant, it is important to have a reliable control system that can handle such real-time changes in system configurations. Traditional PLC-based and non model-driven control systems struggle with such real-time changes of the configuration. ETAP Power Plant Controller (ePPC) is a model-driven solution that simplifies the control and management of multi-area power systems. ePPC can handle real-time changes in system configurations, enabling the controller to adjust quickly to any changes in the power network, ensuring optimal operation of the power plant. Additionally, ePPC uses a digital twin concept that allows for easy configuration and simulation of different system setups. The use of the digital twin concept means that any errors can be identified and resolved before implementation, ensuring efficient and effective setup of the power plant. Overall, ePPC offers a valuable solution for controlling multi-area renewable energy systems, providing real-time control with simple setup and reliable operation.
ETAP Automated Fault Analysis System (AFAS) solution provides Real-Time and advanced analytics of electrical faults for your complex networks. Using the ETAP digital twin combined with disturbance records, engineers and operators have a clear forensic picture of any electrical fault in the network. Using proven ETAP analysis solvers, AFAS identifies faults, including fault type, start time, protection trip time, fault magnitudes, and fault distance/impedances. A novel signal injection features allow users to playback recorded data into the protection model to compare "as designed" vs. "as found" relay response. This comparison using ETAP electrical digital twin is used to validate system response per the configured protection scheme, and the sequence of operation was followed within expected time durations.
FlickerMeter is part of the Power Quality applications in ETAP. FlickerMeter allows importing CSV-formatted data files and analyzes up to 20 signals at each run, to evaluate flicker compliance against emission limits. Flicker calculations comply with IEC 61000-4-15 which is the standard for electromagnetic compatibility (EMC) and the calculation provides instantaneous, short-term (PST), and long-term (PLT) flicker indices based on a voltage waveform loaded into the calculator.
The integration of electric vehicles (EVs), PV systems, battery energy storage systems (BESS), and more has presented us with exciting opportunities and challenges. One such challenge is the need for unbalanced network harmonic analysis, especially when dealing with single-phase charging vehicles and inverter controls.
Discover how this powerful simulation tool evaluates, verifies, and confirms the operation and selectivity of the ZSI scheme for different types of faults. The ZSI capabilities empower engineers and professionals like you to take control of electrical power system protection and analysis, enhance safety, minimize equipment damage, and validate arc flash mitigation techniques and scenarios.
Are you curious about the limitations of short-circuit standards and their inadequacy in addressing arc-flash incident energy calculations? In this presentation, we will review the challenges posed by these standards with an emphasis on IEC 60909-2016 and provide you with an explanation of ETAP arc-flash solutions to these limitations.
When it comes to running an arc flash hazard analysis study, it's crucial to identify equipment that may expose workers to high incident energy. One of the most hazardous areas is where line side arcing faults can occur. To address this challenge, Annex 0.2.3 of the 70E 2021 standard outlines various industry-accepted incident energy mitigation techniques. However, not all methods effectively tackle line side arcing faults. During the demonstration, you will acquire valuable knowledge on NFPA 70E endorsed mitigation techniques as well as details on ETAP modeling of the ArcBlok technology.
ETAP 2023 version 22.5 offers innovative solutions and features with numerous enhancements and time-saving improvements, empowering ETAP customers with technology and best practices to be safer, more reliable, efficient, compliant, and sustainable.
As more Distributed Energy Resources (DERs) are added and mixed into the grid, the need to effectively evaluate and validate the dynamic response of power systems has become essential for grid resiliency, reliability, and security. In this webinar, learn how ETAP's Transient Stability module addresses the needs and challenges of stability studies for power systems with DERs. The module provides comprehensive analysis of the system's behavior during disturbances, enabling engineers to make informed decisions for improving system stability and ensuring grid reliability.
Learn how utility engineers use ETAP’s transmission & distribution system analysis and optimization solutions to optimize capacity planning and improve reliability and safety using schematic or geospatial views. ETAP Grid™ transmission system software integrates transmission network planning with detailed substation models, network topology processing, transmission system analysis, electric SCADA and real-time transmission network energy management system. For integrated distribution network analysis, system planning and operations solution it offers a progressive geospatial platform for simulating, analyzing, operating and optimizing the performance of Utility Smart Grids.
Discover ETAP ADMS™, a combined planning and operation solution to manage, control, visualize, and optimize electrical power distribution networks comprising of: Geospatial Information System (GIS) Electrical Supervisory Control & Data Acquisition (SCADA) Distribution Management System (DMS) Distribution Network Applications (DNA) Outage Management System (OMS) Advanced Distribution Management System must offer flexible solutions to address the core requirement of the new digital grid to provide resiliency and reliability to the network while having the scalability to intelligently and proactively assess the outcome of the operations and contribute to the new requirements to minimize network cost and improve asset optimization. ETAP ADMS offers such an intelligent and robust decision support platform based on a unified Digital Twin of the electrical network with a collection of Geospatial-based distribution network applications integrated with mission-critical operational solutions to manage reliably and securely, control, visualize, and optimize small to vast distribution networks and smart grids.