Интегрированное проектирование и анализ переменного и постоянного тока
Управляемые модели SCADA, EMS, PMS, ADMS и SAS
Интеллектуальные Контроллеры и Система Управления
Единая платформа цифрового двойникаПроектирование, эксплуатация и автоматизация
Filter by
Didn't find what you are looking for? We're here to help!
254 Item(s) found
ETAP NF C15-100 & NF C13-200; Cable Sizing & Shock Protection software module offers a powerful tool to save time and improve accuracy for low & high voltage cable calculation and electrical design using the latest French Cable Standard.
This Cable Thermal Analysis webinar explains how to design cable systems to operate to their maximum potential while providing a secure and reliable operation.
ETAP ArcFault™ software is recommended for performing Arc Flash Analysis on electrical utilities and renewable power systems operating at 15 kV and above.
ETAP Arc Flash Analysis software is used to perform arc flash analysis for systems from 0.208 kV to 15 kV in accordance with IEEE 1584-2018 “IEEE Guide for Performing Arc Flash Hazard Calculations.” The software determines the incident energy and arc flash boundary values required to comply with NEC equipment labeling. It also provides hazard evaluation for shock protection and arc flash PPE according to NFPA 70E 2018.
Этот модуль вычисляет энергию дуги для различных типов оборудования сети постоянного тока.
Arc flash analysis extends well beyond the scope of IEEE 1584 and NFPA 70E methodology for transmission, distribution, industrial and renewable energy systems. For many years, the industry has been lacking an ‘all-in-one’ solution for performing AC and DC arc flash analysis on LV, MV, and HV systems.
This webinar will provide an overview of the fundamental differences between the IEEE 1584-2018 and existing arc flash methods. To better understand how the 2018 model combines empirical and arc flash physical behavior, the presentation will cover background and insights into the model development validation.
Migration from SKM Power*Tools® just got easier, faster and more complete! Convert your SKM Dapper & Captor project files into ETAP power system analysis software.
New Standard, New Method, New Learning Curve
В ходе вебинара «Интеграция ETAP и Revit» мы подробно разберем преимущества выполнения расчётов в ETAP при формировании проектных решений электрической сети и реализации проекта в Revit.
Proper sizing and current de-rating ensures that cables operate to their maximum potential while providing secure and reliable operation. This webinar covers cable sizing, current carrying capacity and electrical shock protection based on IEC and British standards.
The challenges of directional protection of a wind farm collector are presented in this webinar. ETAP StarZ™ Protection & Coordination module is utilized to set and analyze protection of wind power plant collectors.
Per North American Electric Reliability Corporation (NERC), 28% of protective relay mis-operations are due to incorrect settings and logics. These errors mainly stem from the existing relay testing procedures that do not provide a proper mechanism to easily and effectively evaluate the performance of all settings, logics, and the protection system as a whole. ETAP StarZ™ is a new solution to minimize protective relay setting errors and reduce the time required to perform protection and coordination studies.
This webinar presents the fundamentals of harmonics, harmonic distortion and its sources, and related issues such as premature equipment failure or unplanned downtime. The presentation will demonstrate how to identify, analyze, and minimize or eliminate harmonics problems using the ETAP software.
ETAP ADMS™ is a combined planning and operation solution to manage, control, visualize, and optimize electrical power distribution network comprising of GIS, SCADA, DMS, DNA & OMS.
This webinar covers machine fundamentals such as Conversion of Energy, Steady-State Operation, Motor / Generator, Ratings & Motor Equations, Efficiency & Power Factor vs. Loading, Motor Feeder Cable and Load Flow Solutions.
This webinar discusses the induction motor dynamic behavior for acceleration, deceleration and steady-state speed control conditions. It highlights how each of the key fundamental motor dynamic characteristics applies to different applications such as motor starting, fast-bus transfer, and motor parameter estimation and tuning.
This webinar presents the criterion and industry guidelines for protection of motors in medium and low voltage systems, typical induction motor protection schemes and suggested settings for protective devices. The application of Automated Protection & Coordination evaluation tool for design, verification, and correction of settings are also demonstrated.
Vital features and benefits of the modern power management software.
In the absence of a "definitive" DC arc flash model, ETAP includes three calculation models - the "Maximum Power" method that is used in NFPA 70E, a model based on the Stokes/Oppenlander estimate of arc voltage and resistance, and a model based on Paukert's complication of research into arcing faults.