ETAP 113 MX

Power System Analysis

3-Day Workshop
Oct 24 - 26, 2018
México, CDMX , México
Fee: MXN 15,000

DayMorningAfternoon
1

ETAP Menu and Toolbars
Modeling of Power System Components
Manual / Auto Building One Line Diagram
Display Options
Themes and Color Codes
Project Revisioning
3-D Database (Presentation, Configuration, Revision)
ETAP Library Structure
Data Import / Export
Data / Project Management
Scenario Wizards
Exercise

Cable Library
Motor Library
Transmission Line Library
Protective Devices Library
Create, Copy, Merge, Export Functions

Data Requirements
Calculation Methods
Load / Generation Modeling in Power System
Loading / Generation Categories
Diversity / Demand Factors
Parameter Settings / Adjustments
Reports / Alerts
Result Analyzer
Exercise

ANSI Short Circuit Concept & Overview
Data Requirements
ANSI Calculation Method
1/2 Cycle, 4 Cycle, 30 Cycle Short Circuit
Device Duty Calculation
Three Phase Faults
Unbalanced / Ground Faults
Parameter Settings / Adjustments
Reports / Alerts
Result Analyzer
Exercises
2

Protection of Equipment
Data Requirements
Protection Equipment Library
Protection & Selectivity Concepts
Protective Device Arrangements
Time-Current Characteristics
Exercise

Data Requirements
Protection Equipment Library
Protection & Selectivity Concepts
Protective Device Arrangements
Time-Current Characteristics
Protective Device Coordination utilizing Short Circuit
Parameter Settings / Adjustment
Sequence-of-Operation Study
Auto Coordination Concept & Application
Study / Device Setting Reports
Exercise

Protective Device Coordination utilizing Short Circuit
Parameter Settings / Adjustment
Sequence-of-Operation Study
Study / Device Setting Reports Exercise
Auto Evaluation Concept & Application
Auto Evaluation Rule Book
Auto Evaluation of Protection & Coordination on Selected Zones
Errors, Alerts & Warnings
Exercise

3

AC & DC Arc Flash Concept & Overview
Calculation Methods (NFPA 70E and IEEE 1584)
Data Requirements
PPE Requirements
Parameter Settings / Adjustments
Effects of Short Circuit and Protection/Coordination
Reports / Alerts
Result Analyzer
Arc Flash Labels
Exercise

Data Requirements (Rod / Conductor)
Regular / Irregular Ground Grid Modeling
Design Criteria
Calculation Methods / Settings (IEEE 80, FEM)
Reports / Alerts / 3D-Plots
4
5

Workshop Description

  • The purpose of this introductory 3-day hands-on workshop is to learn power system modeling & analysis using ETAP software.
  • This workshop covers a range of ETAP functionalities used to solve various power system practical problems such as equipment sizing in steady state and short circuit conditions, protection of the equipment, selectivity, & device coordination, and arc flash assessment & mitigation.
  • An ETAP workstation is provided for each attendee.

Who should attend

  • New ETAP users and power engineers who wish to increase their skills using the ETAP application to perform system studies.
  • Current users seeking a refresher course.
  • Knowledge of power system engineering concepts is highly recommended for those attending this workshop.

Registration

  • Fee: MXN 15,000

The price does not include IVA.



Location

ETAP Oficina Regional LATAM
Sala de Capacitación
Av. Melchor Ocampo 193 Torre A P13-B
Col. Verónica Anzures
Del. Miguel Hidalgo
11300 México, CDMX México

Date & Time

Oct 24 - 26, 2018
9:00 AM - 6:00 PM
Time zone: UTC

Meal

Coffee break service.  Lunch is not included.

Hotel

All travel and hotel arrangements are the responsibility of the attendees.

Information

Oficina Regional LATAM
Av. Melchor Ocampo 193, Torre A Piso 13 Oficina B Col. Verónica Anzures, Del. Miguel Hidalgo
11300 México, CDMX,
México
+52.5550861867

Ventas.Latam@etap.com

ETAP Training Services | (949) 900-1084 | training@etap.com