ETAP 114 ZA

Power System Analysis

4-Day Workshop
Sep 10 - 13, 2018
Johannesburg, South Africa
Fee: R 12,600
This workshop is conducted and taught by the ETAP authorized representative:  Intergraph Systems Southern Africa
DayMorningAfternoon
1

ETAP Menu and Toolbars
Modeling of Power System Components
Manual / Auto Building One Line Diagram
Display Options
Themes and Color Codes
Project Revisioning
3-D Database (Presentation, Configuration, Revision)
ETAP Library Structure
Data Import / Export
Data / Project Management
Scenario Wizards
Exercise

Data Requirements
Calculation Methods
Load / Generation Modeling in Power System
Loading / Generation Categories
Diversity / Demand Factors
Parameter Settings / Adjustments
Reports / Alerts
Result Analyzer
Exercise

Cable Editor / Library
Cable Manager
Cable Loading
Cable Installation Types / Ampacity
Cable Sizing Standards
Cable Sizing Constraints
Exercise
2

Data Requirements
IEC 909 Calculation Method
Types of Short Circuit in IEC & Factors
Device Duty Calculation in Mesh & Non-Mesh Networks
Unbalanced / Ground Faults
IEC 61363 Transient Fault Current Calculation
Parameter Settings / Adjustments
Reports / Alerts
Result Analyzer
Exercises

Motor and motor starting theory
Static motor starting analysis
Study case editor
Motor parameter estimation
Dynamic motor starting analysis
Plots, display results and reports
3

Protection of Equipment
Data Requirements
Protection Equipment Library
Protection & Selectivity Concepts
Protective Device Arrangements
Time-Current Characteristics
Exercise

Protective Device Coordination utilizing Short Circuit
Parameter Settings / Adjustment
Sequence-of-Operation Study
Study / Device Setting Reports
Exercise

Protective Device Coordination utilizing Short Circuit
Parameter Settings / Adjustment
Sequence-of-Operation Study
Study / Device Setting Reports Exercise
Auto Evaluation Concept & Application
Auto Evaluation Rule Book
Auto Evaluation of Protection & Coordination on Selected Zones
Errors, Alerts & Warnings
Exercise

4

AC Arc Flash Concept & Overview
Calculation Methods (NFPA 70E and IEEE 1584)
Data Requirements
PPE Requirements
Parameter Settings / Adjustments
Effects of Short Circuit & Protection / Coordination
Reports / Alerts
Result Analyzer
Arc Flash Labels
Exercises

Data Requirements
Harmonic Source Modeling
Harmonic Library / Inter-Harmonics
Harmonic Load Flow / Frequency Scan
Parameter Settings / Adjustment
Reports / Alerts / Plots
Exercise
5
6
7

Workshop Description

  • The purpose of this 4-day introductory hands-on workshop is to learn power system modeling & analysis using ETAP software.
  • This workshop covers a range of ETAP functionalities used to solve various power system practical problems such as equipment sizing in steady state and short circuit conditions, motor acceleration scenarios, protection of the equipment, selectivity, & device coordination, arc flash assessment & mitigation, and effects of harmonics in the system.

Who should attend

  • New ETAP users and power engineers who wish to increase their skills using the ETAP application to perform system studies.
  • Current users seeking a refresher course.
  • Knowledge of power system engineering concepts is highly recommended for those attending this workshop.

Registration

Fee: R 12,600




Location

Intergraph Systems Southern Africa
2nd Floor, Building 1, Golder House
Maxwell Office Park, Magwa Crescent West
Waterfall City, Midrand
Johannesburg, South Africa

Date & Time

Sep 10 - 13, 2018
8:00 AM - 4:30 PM

Meal

Snacks, beverages, and lunch are included with the registration fee.

Hotel

All travel and hotel arrangements are the responsibility of the attendees.

Information

Intergraph Systems Southern Africa
3rd Floor, Building I, Hertford Office Park, 90 Bekker Road,
Vorna Valley, Midrand 1686
South Africa
+27 11 231 1400

info@intergraph.co.za

ETAP Training Services | (949) 900-1084 | training@etap.com