ETAP 114 NG

Power System Analysis

4-Day Workshop
Jun 20 - 23, 2017
Lagos, Nigeria
Fee: N 200,000
This workshop is conducted and taught by the ETAP authorized representative:  Gil Automations Limited-Nigeria
DayMorningAfternoon
1

ETAP Menu and Toolbars
Modeling of Power System Components
Manual / Auto Building One Line Diagram
Display Options
Themes and Color Codes
Exercise

3-D Database (Presentation, Configuration, Revision)
ETAP Library Structure
Data Import / Export
Data / Project Management
Scenario Wizards
Exercise
2

Data Requirements
Calculation Methods
Load / Generation Modeling in Power System
Loading / Generation Categories
Diversity / Demand Factors
Parameter Settings / Adjustments
Reports / Alerts
Result Analyzer
Exercise

Data Requirements
IEC 909 Calculation Method
Types of Short Circuit in IEC & Factors
Device Duty Calculation in Mesh & Non-Mesh Networks
Unbalanced / Ground Faults
IEC 61363 Transient Fault Current Calculation
Parameter Settings / Adjustments
Reports / Alerts
Result Analyzer
Exercises
3

AC Arc Flash Concept & Overview
Calculation Methods (NFPA 70E and IEEE 1584)
Data Requirements
PPE Requirements
Parameter Settings / Adjustments
Effects of Short Circuit & Protection / Coordination
Reports / Alerts
Result Analyzer
Arc Flash Labels
Exercises

Motor and motor starting theory
Static motor starting analysis
Study case editor
Motor parameter estimation
Dynamic motor starting analysis
Plots, display results and reports

Motor and motor starting theory
Static motor starting analysis
Study case editor
Motor parameter estimation
Dynamic motor starting analysis
Plots, display results and reports

Protection of Equipment
Data Requirements
Protection Equipment Library
Protection & Selectivity Concepts
Protective Device Arrangements
Time-Current Characteristics
Exercise

4

Data Requirements
Protection Equipment Library
Protection & Selectivity Concepts
Protective Device Arrangements
Time-Current Characteristics
Protective Device Coordination utilizing Short Circuit
Parameter Settings / Adjustment
Sequence-of-Operation Study
Auto Coordination Concept & Application
Study / Device Setting Reports
Exercise

Data Requirements
Protection Equipment Library
Protection & Selectivity Concepts
Protective Device Arrangements
Time-Current Characteristics
Protective Device Coordination utilizing Short Circuit
Parameter Settings / Adjustment
Sequence-of-Operation Study
Auto Coordination Concept & Application
Study / Device Setting Reports
Exercise
5
6
7

Workshop Description

  • The purpose of this introductory hands-on workshop is to learn power system modeling & analysis using ETAP software extended to four days.
  • This workshop covers a range of ETAP functionalities used to solve various power system practical problems such as equipment sizing in steady state and short circuit conditions, motor acceleration scenarios, protection of the equipment, selectivity, & device coordination, and arc flash assessment & mitigation.
  • An ETAP workstation is provided for each attendee.
 

Who should attend

  • New ETAP users and power engineers who wish to increase their skills using the ETAP application to perform system studies
  • Current users seeking a refresher course
  • Knowledge of power system engineering concepts is highly recommended for those attending this workshop

Registration

Fee: N 200,000




Location

Daily Times Complex Text
Lateef Jakande Road
Ikeja
Lagos
Nigeria

Date & Time

Jun 20 - 23, 2017
9:00 AM - 4:00 PM

Meal

Lunch and tea breaks are included with the registration fee.

Hotel

All travel and hotel arrangements are the responsibility of the attendees.

Information

Gil Automations Limited-Nigeria
Daily Times Complex Lateef Jakande Rd, Agidingbi
Ikeja, Lagos State
Nigeria
+234 805 502 7048
+234 8478 3400
etap@gilautomation.com

ETAP Training Services | (949) 900-1084 | training@etap.com