Resource Center

Prime content - login required
High Voltage Arc Flash Assessment and Applications

High Voltage Arc Flash Assessment and Applications

Two-part technical article published by the InterNational Electrical Testing Association (NETA) in NetaWorld, co-authored by Albert Marroquin, VP of V&V at ETAP.

Ground Grid Design Made Simple

Ground Grid Design Made Simple

28:47 Webinars

In this webinar, learn how to obtain accurate and economical ground grid designs by quickly identifying appropriate ground grid layouts, while efficiently conducting studies using integrated fault analysis tools. 

ETAP ArcFault™ - High Voltage Arc Flash Analysis

ETAP ArcFault™ - High Voltage Arc Flash Analysis

ETAP ArcFault™ software is recommended for performing Arc Flash Analysis on electrical utilities and renewable power systems operating at 15 kV and above.

ETAP Arc Flash IEEE 1584-2018

ETAP Arc Flash IEEE 1584-2018

ETAP Arc Flash Analysis software is used to perform arc flash analysis for systems from 0.208 kV to 15 kV in accordance with IEEE 1584-2018 “IEEE Guide for Performing Arc Flash Hazard Calculations.” The software determines the incident energy and arc flash boundary values required to comply with NEC equipment labeling. It also provides hazard evaluation for shock protection and arc flash PPE according to NFPA 70E 2018.

ETAP DC Arc Flash Session Part 1-3

ETAP DC Arc Flash Session Part 1-3

30:00

The topics that will be discussed in this video are the characteristics of an Arc, DC Short Circuit calculations, the Maximum Power Method, the Stokes and Oppenlander Method, Paukert Method, how these methods are utilized in ETAP, the calculation of incident energy, how to configure ETAP 11.1 to determine whether or not you are dealing with an open or closed air equipment, and the result analyzer.

ETAP Arc Flash Overview Part 1-6

ETAP Arc Flash Overview Part 1-6

1:00:00

ETAP Arc Flash Analysis automatically estimates the Incident Energy released in the event of an arc fault and determines the required Flash Protection Boundary.

ETAP 18 - Modeling and Deliverables

ETAP 18 - Modeling and Deliverables

41:28 Webinars

ETAP 18 offers a powerful set of new features and capabilities for system modeling, analysis, and operations. This webinar covers many time-saving enhancements in addition to the new reports and deliverables to improve productivity and user experience.

High Voltage Arc Flash for T&D, Industrial and Renewable Systems

High Voltage Arc Flash for T&D, Industrial and Renewable Systems

1:12:23 Webinars

Arc flash analysis extends well beyond the scope of IEEE 1584 and NFPA 70E methodology for transmission, distribution, industrial and renewable energy systems. For many years, the industry has been lacking an ‘all-in-one’ solution for performing AC and DC arc flash analysis on LV, MV, and HV systems.

20 of 21 results