DC control systems diagram software

ETAP seamlessly integrates the analysis of power and control circuits within one electrical analysis program. The Control System Diagram (CSD) simulates the sequence-of-operation of control devices such as solenoids, relays, controlled contacts, multi-sequence contacts, and actuators including inrush conditions.

CSD has the capability of determining pickup and dropout voltages, losses, and current flows at any time instance as well as overall marginal and critical alerts. A large library of equipment enables engineers to quickly model and simulate the action of relays associated with control interlocks after given time delays.

Key Features
dc control systems diagram software
  • Simulation of operation sequence
  • Pickup & dropout voltage calculation
  • Automatic alerts
  • Burden & inrush modes
  • Controlled contacts
  • Integrated with battery discharge calculation
Capabilities
  • Detailed representation of control systems
  • Step-by-step simulation of control system operation sequence
  • Simulation of logic interlocks between controlling devices & contacts
  • Calculation of device operating voltage & current
  • Modeling of device burden & inrush modes
  • Alert violations for operating voltage, current, & voltage pickup
  • Built-in logic between control devices & contacts
  • Multiple sources to a control system
  • User’s selectable modeling of protective device & contact resistance
  • Coil/solenoid resistance temperature adjustment
  • Cable/wire length adjustment
  • Battery discharge calculation using sequence-of-operation control diagrams
dc control systems diagram software - determine pickup and dropout voltages, losses and current flows at any time instance
Elements
  • Extensive libraries
  • Control relay
  • Coil
  • Solenoid
  • Light
  • Generic load
  • Wire
  • Fuse
  • Circuit breaker
  • Single-throw & double-throw controlled contacts
  • Single-throw & double-throw switches
  • Macro-controlled contacts
Features
  • Graphical animation of complex control logic with or without voltage drop calculation
  • Include time-dependent loads of control systems in battery discharge & sizing calculation
  • Operator initiated control actions and/or auto-run mode
  • Display and alert overloading as well as pickup/dropout voltage violations
  • Flexible device modeling with user-defined duty cycle or actual inrush/burden rating
  • Validate the voltage requirements of controlling devices
  • Generate automatic alerts for pickup & dropout voltage
  • View detailed operating states of the devices with Event Viewer
Study Cases
dc control systems diagram software
  • Saves solution control parameters for each scenario
  • Make changes to your system & re-run studies instantly
  • Conduct unlimited "what if" studies within one database
  • Option to update initial conditions, voltage profiles, & duty cycles
Customized Display Options
  • Device names & ratings
  • Equipment impedance
  • Font types, sizes, styles, & colors
  • Voltage drop calculation results directly on the one-line diagram
  • Dynamically adjust the display of calculation results
Reporting
  • Customize output reports using Crystal Reports
  • Generate output reports in any language
  • Voltage drops, losses, power flows, etc.
  • Sequence of operation action summary log
  • Input data, detailed voltage drop, & summaries
  • Flag device pickup/dropout voltage violations
  • Flag element current violations
  • State-of-the-art graphic display of results
  • Export outputs to your favorite word processing program
  • Export one-line diagrams including results to third party CAD systems